7.Section 4 contains all of the default Jumper Settings, if it is necessary for you to manually configure the interface.

Troubleshooting Guide

Problem

Solution

 

 

Red LED is not

Check to make sure the power transformer is plugged

illuminated

in properly.

 

 

 

Replace power transformer.

 

 

Cannot display

Make sure the Triplex is showing the text box on

demo text

Monitor A.

 

 

 

Dip switch setting should be SW1: ON ON OFF ON

 

 

 

Check that the serial cable is plugged into Port

 

RS232/2 on the Triplex and Port 1 of the PB3 with the

 

RJ45 to RJ45 cable (4310-0034B).

 

 

 

Ensure the baud rate for Port 2 (RS232) on the Triplex

 

is set to 19200 bps.

 

 

 

Ensure camera addresses are set correctly.

 

 

Cannot connect

Check cable connection.

with HyperTerminal

 

 

 

 

Ensure the computers com port is enabled in the

 

system bios and Windows control panel.

 

 

 

Verify HyperTerminal’s communication settings are

 

19200, 8, N, 1, no flow control.

 

 

Kalatel CBR-PB3-WD