7.Section 4 contains all of the default Jumper Settings, if it is necessary for you to manually configure the interface.
Troubleshooting Guide
Problem | Solution |
|
|
Red LED is not | Check to make sure the power transformer is plugged |
illuminated | in properly. |
|
|
| Replace power transformer. |
|
|
Cannot display | Make sure the Triplex is showing the text box on |
demo text | Monitor A. |
|
|
| Dip switch setting should be SW1: ON ON OFF ON |
|
|
| Check that the serial cable is plugged into Port |
| RS232/2 on the Triplex and Port 1 of the PB3 with the |
| RJ45 to RJ45 cable |
|
|
| Ensure the baud rate for Port 2 (RS232) on the Triplex |
| is set to 19200 bps. |
|
|
| Ensure camera addresses are set correctly. |
|
|
Cannot connect | Check cable connection. |
with HyperTerminal |
|
|
|
| Ensure the computers com port is enabled in the |
| system bios and Windows control panel. |
|
|
| Verify HyperTerminal’s communication settings are |
| 19200, 8, N, 1, no flow control. |
|
|