Temperature settings can range from 45° to 90° Fahrenheit.

High

Setpoint

90°

Ifroomtemperature reacheshighsetpoint, airconditionerturnson.

Ifroomtemperature reacheslowsetpoint, furnaceturnson.

Low

Setpoint

45°

Note

Disarming the system turns off the Energy Saver.

Figure 5.Energy Saver Setpoints

To set the Energy Saver temperature range from a touchpad:

1.Enter the programming menus by pressing 9 + System or Partition Master CODE.

2.Press 070.

3.Enter the lowest temperature (45–89°F) you’ll allow before the furnace turns on, and press #.

4.Press B. Enter the highest temperature (46–90°F) you’ll allow before the air conditioner turns on, then press #.

5.Press * + 00 + # to exit the programming menus.

To override your normal heating or air conditioning settings, turn the Energy Saver feature on. When you are ready to return to your normal temperature control settings, turn Energy Saver off.

To turn Energy Saver on/off from any touchpad:

1. Press 7 + 2. Alphanumeric touchpads display, “ENERGY SAVER IS ON,” for example.

Notification by Your system can notify up to five different pager phone numbers to report system events. The

Pagerinstaller can program any numeric pager to receive pages for one or more of the following groups.

High Level Reports

Low Level Reports

 

 

 

 

Sensor Alarms

Freeze Alarms

Bypass Sensors

AC Power Failure

 

 

 

 

Tamper

Freeze Troubles

Low Battery

CPU Low Battery

 

 

 

 

Restorals

No Activity Alarm

Supervisory

Auto Phone Test

 

 

 

 

Phone Tests

Fire Panic

Trouble

CPU Back in Service

 

 

 

 

Receiver Failure

Police Panic

Phone Test

Phone Failure

 

 

 

 

Receiver Jam

Auxiliary Panic

Event Buffer Full

Touchpad Low Battery

 

 

 

 

Touchpad Tamper

 

 

 

Bus Failures

 

 

 

 

 

 

 

• Opening and Closing Reports

• Latchkey Reports

• Notify by Exception Reports

18