Phone Communication Test

Device

Test Procedure

Touchpad Result(s)

 

 

 

Touchpad

Trip a:

 

 

Touchpad Panic POLICE OK

 

Police panic alarm,

 

 

Touchpad Panic FIRE OK

 

Fire panic alarm, and

 

 

 

Auxiliary panic alarm.

 

 

Touchpad Panic AUXILIARY OK

 

 

 

 

POLICE PANIC OK

 

 

 

 

FIRE PANIC OK

 

 

 

 

AUXILIARY PANIC OK

 

 

 

 

 

 

Wireless Touchpad

Press the Bypass key.

 

 

Zones nn OK

 

 

 

 

TOUCHPAD nn OK

 

 

 

 

 

 

Keychain Touchpad

Press and hold the Lock

and Unlock

buttons

Zones nn OK

 

simultaneously for 3 seconds.

 

TOUCHPAD nn OK

 

 

 

 

 

 

 

Press and hold the Star

and Light

buttons

Touchpad Panic AUXILIARY OK

 

simultaneously for 3 seconds.

 

AUXILIARY PANIC OK

 

 

 

 

Panic button

Press and hold the appropriate panic button(s) for 3

Zones nn OK

 

full seconds.

 

 

SENSOR nn OK

 

 

 

 

 

 

 

 

 

Door/window sensor

Open the secured door or window.

 

Zones nn OK

 

 

 

 

SENSOR nn OK

 

 

 

 

Smoke detector

Press and hold the test button until the system sounds

Zones nn OK

 

transmission beeps.

 

 

SENSOR nn OK

 

 

 

 

 

 

 

 

Motion detector

Avoid the motion detector view for 5 minutes, then

Zones nn OK

 

enter its view.

 

 

SENSOR nn OK

 

 

 

 

 

 

 

Rate-of-Rise Heat Detec- Rub your hands together until warm, then place one

Zones nn OK

tor (Not UL investigated)

hand on the detector for 30 seconds.

 

SENSOR nn OK

 

 

 

 

 

 

 

 

Shock sensor

Tap the glass twice, away from the sensor. Wait at

Zones nn OK

(Not UL investigated)

least 30 seconds before testing again.

 

SENSOR nn OK

 

 

 

 

 

 

 

 

Phone Interface and

Activate a Police panic by accessing the system using

POLICE PANIC OK

Voice Module

the phone and pressing * + * + * + * + * + *.

 

 

Glass guard sensor

Tap the glass 3 or 4 inches from the sensor.

Zones nn OK

(Not UL investigated)

 

 

 

SENSOR nn OK

 

 

 

 

 

 

 

 

Freeze sensor

Apply an ice cube wrapped in plastic to the sensor. Do

Zones nn OK

(Not UL investigated)

not allow the sensor to get wet.

 

SENSOR nn OK

 

 

 

 

If you need more time to complete testing, restart the timer by pressing 8 + CODE + 3.

Check to see that all sensors have been tested by pressing *. Touchpads display a list of untested sensors.

You will know that you have finished testing when touchpads display, “SENSOR TEST OK” or “ZONES ALL TESTED.”

4.Disarm to Level 1—Off to exit Test Mode.

Phone Communication Test

The purpose of this test is to verify communication between the central monitoring station and your system.

Most phone tests take only a few minutes, however, your system will try for up to 15 minutes to establish a connection if necessary.