Installation Instructions

INSTALLATION CHECKLIST

1. Tank location:

Is room size less than 10' x 10' x 7' (700 cu. ft.)? If yes, louvered door or similar ventilation is needed.

Back of unit away from wall by 7 inches.

Front of unit is free and clear.

Is the water heater level? If no, add shims under the base of the unit.

2. Plumbing connections:

Does not prevent air filter removal.

No leaks after filling the tank with water, either when water is flowing or not.

3. Condensate lines are in place:

1)Short tube on upper drain nozzle.

2)Longer tube on lower drain nozzle and directed into a floor drain or a condensate pump.

4. Temperature and pressure-relief valve is working and drain line completed per local code.

5. Electrical connection does not prevent air filter removal.

6. Verify control panel displays 120°F Hybrid mode.

7. Front cover is in place.