3-4 MDS Intrepid-HC HP Installation and O peration
SITE ACCEPTANCE CHECKLIST
(continued)
7. FLEXIBLE WAVEGUIDE
Flexible WG ty pe:
Flexible WG is connected securely to RFU and Antenna OK
Flexible WG connector is weather-proofed (sealed) at the
RFU OK
At the RFU, the flexible WG has a service/drip loop to
prevent moisture from entering the connector OK
Flexible WG is secured using suitable restraints to fixed
points at regular intervals (0.5 m recommended) OK
Flexible WG has no sharp bends, kinks, or crushed areas.
All bends are per manufacturer specifications OK
Flexible WG ends are properly labeled OK
8. IN-DOOR UNIT
IDU is securely mounted to the rack OK
IDU is located in a properly ventilated environment OK
IDU fans are functional and air flow to the fans is not
disrupted OK
IDU and rack are grounded as per site specifications OK
Traffic cables and connections are properly terminated as
per manufacturer/cable instructions OK
All cabling is secured, tidy, and visibly labeled OK
9. DC POWER SUPPLY - Two In puts
Measured DC voltage input to the IDU: (-40.5 to -72 VDC)
Power-Supply maximum current: (at least 3 Amperes)
Power-Supply is properly grounded OK
DC power backup type:
IDU DC connector is secure and the DC input leads are
correctly terminated (no bare wires are visible) OK
IDU DC connector (+) and (GND) leads are shorted an d
GND is grounded OK
10. RACK INSTALLATION
Rack is mounte d to the shelter floor w ith four screws OK
Rack is mounte d to the shelter wall w ith two screws OK