CH.1: INTRODUCTION 06 Apr 2000 PAGE 11
GFK-1819
1.3 Technical SpecificationsTable 1.2 Technical Specifications
Parameter Conditions Min. Typical Max. Units
Input voltage (VI)102432VDC
Typical power consumption
TIU050
TIU10X
TIU11X
TIU20X
VI = 24VDC
VI = 24VDC
VI = 24VDC
VI = 24VDC
130
130
130
350
mA
Inrush input current VI = 24VDC for 4ms 260 mA
Operating tem perature
TIU050
TIU10X
TIU10X-6
TIU11X
TIU11X-6
TIU20XA
TIU20XB or higher
0
0
-10
0
-10
0
0
50
50
60
50
60
45
50
°C
Storage temper ature -20 70 °C
Relative Humidity (non-condensing) 10 90 %
Weight
TIU050
TIU10X
TIU11X
TIU20X
320
370
470
1870
350
400
500
1900
g
Dimensions
TIU050
TIU10X
TIU11X
TIU20X
179 x 111 x 60
121 x 105 x 38
172 x 105 x 38
282 x 194 x 62
mm
Cable Lengths
RS-232
RS-485 1 15
1500 m
IP rating NEMA 4-12/IP65
EMC Conformance EN 55 022, Radiated and Conducted Emissions
EN 61000-4-3, Radiated and Conducted RF Immunity
ENV 50144
Cables beyond the maximum recommended length may create communication problems. Both ends of
an RS-485 network must be properly terminated at 120 and grounded.