![Feature: Program Memory](/images/new-backgrounds/200579/20057923x1.webp)
Safety Information
Operating Instructions
Troubleshooting Tips
Customer Service
About the water softening system.
Feature: Program Memory
If electrical power to the water softening system is interrupted, the time display is blank, but the timer keeps correct time for about 72 hours. When power is restored, you have to reset the present time only if the display is flashing. All other settings are maintained and never require resetting unless a change is desired.
If the time is flashing after a long power outage, the water softening system continues to work as it should to provide you with soft water. However, regenerations may occur at the wrong time of day until you reset the timer to the correct time of day.
Feature/Service: Automatic Electronic Diagnostics
The timer computer has a
The chart on Error Codes, shows the error codes that could appear and possible defects for each code. While an error code is displayed, the TOUCH or HOLD and DATA buttons remain operable so you can perform the Manually Initiated Electronic Diagnostics.
ERROR CODE DISPLAYED | ERR 01 | ERR 02 | ERR 03 | ERR 04 | ERR 05 |
POSSIBLE DEFECT | • motor | • position | • motor | • position | • timer |
| inoperative | switch | inoperative | switch or | (PWA) |
|
|
| or wiring | wiring |
|
|
|
| harness | harness |
|
| • wiring harness | • timer | • timer | • timer |
|
| or connection | (PWA) | (PWA) | (PWA) |
|
| to switch |
|
|
|
|
| • position switch |
|
|
|
|
| • timer (PWA) |
|
|
|
|
|
|
|
|
|
|
To remove an error code: (1) Unplug transformer.
(2)Correct defect.(3)Plug transformer in.
(4)Wait for at least 6 minutes. The error code will return if the reason for the error code was not corrected.
12