GE PNSF39Z01 Service Manually Initiated Electronic Diagnostic, Safety, Information, Displays

Models: PNSF39Z01

1 28
Download 28 pages 26.21 Kb
Page 16
Image 16
Service: Manually Initiated Electronic Diagnostic

Information

About the water softening system.

Service: Manually Initiated Electronic Diagnostic

Safety

Operating Instructions

Troubleshooting Tips

Customer Service

RECHARGE

WATER MANAGEMENT SYSTEM

x 10

DAY

BThis display segment (SafetyDISPLAYSManual background ), in the following chart, indicates an open POSITION switch. The other indicates a closed switch. Use the TOUCH or HOLD button to manually advance the valve into each cycle and check correct switch operation.

CORRECT SWITCH

 

DISPLAYS

VALVE CYCLE STATUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve in service, fill, brining,

 

 

 

 

 

 

 

 

backwash or rinse position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve rotating from one

 

 

 

 

 

 

 

 

position to another.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Press the DATA button again. This diagnostic display shows the total number of recharges (top) since the timer was connected to electrical power.

The number of days since the timer was connected to electrical power is shown in the bottom part of the display. If over 1999 days, a (x10) indicator shows, meaning you must multiply the number shown by 10.

3 Press DATA once again to return the present time to the display.

16

Page 16
Image 16
GE PNSF39Z01 Service Manually Initiated Electronic Diagnostic, Safety, About the water softening system, Information