Safety Information
Operating Instructions
About the water softening system.
Service: Timer/Water Softening System, Service Checkout Procedure
If you are not getting soft water, and an error code is not displayed, use the procedures below to find the problem. First make the following visual checks.
VISUAL CHECKS: |
|
| Is there electrical power to the outlet the water | |
1 |
| |||
|
|
|
| softening system transformer is plugged into? |
|
|
|
| Is there sufficient salt in the storage tank? |
2 | ||||
|
|
|
| Is the plumbing bypass valve directing water |
3 | ||||
|
|
|
| for soft water service? |
|
|
|
| Is the valve drain hose open to the drain, not |
4 | ||||
|
|
|
| elevated too high, and unobstructed? |
NO SOFT |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| TIMER SHOWS WRONG |
|
|
| Electrical power was off. |
|
|
| Investigate reason for power loss. | |||
WATER |
|
|
| TIME AND DAY, AND/OR |
|
|
| Reset the correct time of |
|
|
|
|
| |
|
|
| FLASHING. |
|
|
| day. |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Customer Service
|
|
|
| Check electrical power to |
|
TIMER DISPLAY |
|
|
|
| |
|
|
| timer (outlet, transformer, |
| |
BLANK. |
|
|
|
| |
|
|
| power cable, all connections). |
| |
|
|
|
|
| |
|
|
|
|
|
|
TIMER DISPLAY SHOWS CORRECT |
|
| Do manual |
TIME AND DAY AND IS STEADY. |
|
| diagnostics. |
|
|
|
|
NO POWER
POWER OK
REPAIR AS NEEDED
TIMER DEFECTIVE
Do manual diagnostics to verify proper function.