To remove the control panel bracket:

To remove the control panel bracket:

1.Remove the control panel. (See Control Panel Assembly.)

2.Disconnect wire harnesses from the relay board at location CN3 and from the power board at location CN4.

3.Peel back the foam tape and release the wire harness to CN4 from the wire retainer.

4.Remove the 4 Phillips-head screws (2 on each side) from the control panel bracket.

5.Slide the control panel bracket to the right then lift the control panel bracket from the control panel.

6.Guide the disconnected harnesses through the wire entry hole in the control panel bracket.

Wire Retainer

Wire Entry Hole

Foam Tape

To remove the control board:

1.Remove the control panel bracket. (See Control Panel Assembly.)

2.Disconnect the 20-pin harness connector from the display board.

3.Disconnect the wire harnesses from the selector board at locations CN9 and CN13.

4.Remove the 4 Phillips-head screws that hold the control board to the control panel.

To remove the display board:

The display board is attached to the control panel by 2 Phillips-head screws and positioned by 2 pins. The display board connects to the control board with a 20-pin wire harness. To access the display board it is necessary to remove the control panel bracket. (See Control Panel Assembly.)

Pin

Pin

20-Pin Wire Harness

 

(Continued Next Page)

– 27 –

Page 27
Image 27
GE SCB 1000, ZSC 1001 manual To remove the control panel bracket, To remove the control board, To remove the display board