Convection Heater Element

Convection Heater Element

The convection heater assembly is held in place by two 7-mm hex-nuts and 4 Phillips-head screws The convection heater element has an approximate resistance value of 9.5 . Two Phillips-head screws connect the power wires to the element terminals.

Convection Fan Motor

The convection fan motor wire leads have locking tabs that must be depressed to be disconnected. To remove each wire from the fan motor, depress the clip using a small blade screwdriver and pull the wire off the terminal as shown.

The convection heater element is held in place by 4 Phillips-head screws. (Three screws on the front, and 1 screw on the end.)

End View of Element

ELECTRICAL TERMINAL

RELEASE/LOCKING TAB

The outer convection fan must be removed before removing the motor. The outer convection fan is held in place by a 7-mm nut, lockwasher, spacer and flat washer.

Front View of Outer Convection Fan

The convection fan motor is held in place by 3 Phillips-head screws .

Rear View of Convection Fan

Convection Fan Motor