Fuse

 

 

 

 

 

 

The oven lamp is inserted in a socket that is attached to the lamp housing with 2 Phillips-head screws. The screws are recessed from the top of the outer cover. Access holes are provided. A magnetic screwdriver is necessary to capture these screws.

It is necessary to remove the control panel to access the oven lamp. (See Control Panel Assembly.)

The oven cavity light will come on during a microwave cooking cycle.

Important Note: The primary interlock, monitor interlock, door sensing (secondary interlock) switches, and the relay board must all be replaced when the 20 amp fuse opens due to operation of the monitor interlock switch.

The unit is equipped with a 20 amp fuse (Part # WB27X10388).

The fuse is located in a receptacle near the top of the noise filter and is common to all functions and door switches.

Fuse

Note: If the fuse opens, it will disable all oven functions including the display. The oven must be partially removed to access the fuse. (See Oven

Removal / Partial Removal.)

Caution: Do not twist the lamp.

The oven lamp is a 130-VAC, 20-watt lamp (Part #

WB08X10050). It is a plug-in type lamp.