Genie 3452535556 GCG manual FCC and IC CERTIFIED, Contact Reverse Test, contact reverse, Testing

Models: 3452535556 3452535556 GCG 3452535556 PCG

1 27
Download 27 pages 47.29 Kb
Page 20
Image 20
CONTACT REVERSE TEST

 

 

CONTACT REVERSE TEST

 

 

The force adjustments and limit switch

 

 

settings MUST BE COMPLETED before testing

 

 

contact reverse.

 

 

1. Testing.

20

 

Open garage door using wall control.

 

Place a 2" x 4" board (laid flat) under center

 

 

of garage door opening (Fig. 7-5).

 

 

Close door using wall control.

 

 

When door hits board, it must stop and

 

 

reverse (within 2 seconds) to open position.

 

 

2. Adjustment.

 

 

Door does not properly reverse.

 

 

Check to see if door is at “close” limit.

 

 

It should not have reached limit switch

 

 

before hitting board.

 

 

Door is at close limit switch.

 

 

Move limit switch closer to door.

 

 

Test again. Repeat as necessary.

 

 

Door is not reaching “close” limit, but

 

 

still does not reverse.

 

 

Decrease “CLOSE FORCE “ setting

 

 

slightly (turn it counter-clockwise).

 

 

Test again. Repeat as necessary.

 

 

 

7PROGRAMMING REMOTE CONTROLS

SINGLE BUTTON REMOTE

1.Programming.

Locate learn code button and indicator LED on front of power head (under force adjustment screws) (Fig. 8-1).

Press and release learn code button.

Indicator LED will blink at a rate of twice per second.

Within 30 seconds, push remote control button once.

Indicator LED will stop blinking and stay on.

Press remote control button again.

LED will go out. Remote is now programmed.

2.Operating.

Press remote button once.

Door will move.

Press button again.

Door will stop.

Press button again.

Door will move in opposite direction.

The door will stop automatically at the fully open or fully closed position.

FIG. 7-5 2 x 4 under center of door opening

FCC and IC CERTIFIED

This device complies with FCC Part 15 and RSS 210 of Industry Canada. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which may be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Re-orient or relocate the receiver antenna.

Increase the separation between the operator and receiver.

Connect the operator into an outlet on a circuit different from that to which the receiver is connected.

Consult your local dealer.

FIG. 8-1 Learn code button and LED

Page 20
Image 20
Genie 3452535556 GCG FCC and IC CERTIFIED, Contact Reverse Test, Programming Remote Controls Single Button Remote, Testing