Genie 3452535556 PCG, 3452535556 GCG manual Safe-T-Beam Alignment Check, With Permanent Wiring

Models: 3452535556 3452535556 GCG 3452535556 PCG

1 27
Download 27 pages 47.29 Kb
Page 18
Image 18
5CONNECTING TO POWER WITH GROUNDED PLUG:

5CONNECTING TO POWER WITH GROUNDED PLUG:

 

 

WARNING

 

 

To reduce the risk of electrical shock, this

18

 

equipment has a grounded type plug that includes

 

 

a third (grounding) pin. This plug will only fit a

 

 

grounded type outlet. If you do not have a

 

 

 

grounded outlet, contact a qualified electrician to

 

 

install one. DO NOT alter the plug in any way. The

 

 

door operator must be properly grounded in order

 

 

to prevent personal injury and damage to

 

 

the components.

 

 

 

1.Plug the operator into a properly grounded electrical outlet. CAUTION

Check local building codes to make sure that you are not required to have your garage door operator permanently wired, with circuit breaker protection.

If permanent wiring is required, have this installed by a qualified electrician.

1.Plug the operator into a properly grounded electrical outlet.

2.Check Safe-T-Beam®alignment (Fig. 6-3).

WITH PERMANENT WIRING:

2.Check Safe-T-Beam®alignment (Fig. 6-3).WARNING

The electrical power to the door operator MUST BE turned off when the motor cover is removed. Electrical power must remain off while making electrical connections.

1.Instructions for electrician.

Remove power from circuit.

Remove motor cover (Fig. 6-1).

Removing hex head screw located in center on bottom of cover.

Slide cover down and off.

Remove and throw away existing power cord.

Remove 7/8" knockout plug (Fig. 6-2).

Install a suitable entrance bushing.

Connect permanent wiring to power head.

White to white/black to black / ground to green.

Use only UL recognized wire nuts.

Wires inside power head must be at least 6" in length.

WITH PERMANENT WIRING: CAUTION

The circuit board is light sensitive. Make sure the motor cover has been replaced prior to re-energizing the circuit.

Replace motor cover and re-energize the circuit.

2.Check Safe-T-Beam®alignment (Fig. 6-3).

NOTE: The Genie Company is not responsible for charges resulting from work performed by an independent electrician.

FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM

screw

FIG. 6-1 Removing motor cover.

knock-out plug

FIG. 6-2 Knock-out plug.

Safe-T-Beam®Alignment Check

After turning the electrical power on, if the STBs are not in proper alignment, the red LED (Source) will blink continuously.

To correct the problem the brackets are flexible and can be adjusted slightly to bring the system into alignment.

When the STBs are in alignment the red LED will stop blinking and stay on.

FIG. 6-3

NOTE: If a problem exists with the “STB” that is preventing the door from closing, the door can be closed by holding the wall control button in until the door is fully closed. (The remote control will not work.)

Page 18
Image 18
Genie 3452535556 PCG manual Safe-T-Beam Alignment Check, With Permanent Wiring, Connecting To Power With Grounded Plug