Genie 4042 Sectional Door, One-Piece Door, 3’ - 4’, Safe-T-Beam STB SYSTEM CHECK, 1 Door balance

Models: 4042

1 72
Download 72 pages 30.82 Kb
Page 18
Image 18
Safe-T-Beam® (STB) SYSTEM CHECK

–CONTACT A TRAINED DOOR SYSTEM TECHNICIAN. WARNING

Garage door hardware (springs, cables, brackets, pulleys, etc.) are under extreme pressure and tension.

DO NOT attempt to repair or adjust door

springs or any hardware, and DO NOT OPERATE garage door automatically or manually if door is improperly balanced or springs are broken.

ROUTINE MONTHLY MAINTENANCE WARNING

Use wall console supplied with opener. Other approved wall consoles may be available. Unapproved or incompatible wall consoles can cause the opener to operate unexpectedly.

Safe-T-Beam® (STB) SYSTEM CHECK

• STB Red and Green LEDs ON steady, system OK

CONTACT A TRAINED DOOR SYSTEM TECHNICIAN.

ROUTINE MONTHLY MAINTENANCE

Basic monthly maintenance tasks.

Safe-T-Beam® System Check

Door balance

Contact reverse

Instructions for these tasks and others are found on

STB Red LED flashes

Check for obstruction

Check alignment

Verify wire routing from STBs to STB connection in powerhead

Check for signal interference from another Safe-T-Beam® unit

FROM STBs

STB

FROM WALL

CONSOLE

•Safe-T-Beam® System CheckNOTDOOR BALANCE (SPRING TENSION)NOT

USED USED

BWC IWC

the following pages.

DOOR BALANCE (SPRING TENSION)

No STB Red or Green LED displayed

Check wiring and wire connections

With the door closed, pull 3’ - 4’ release handle DOWN and let go to release door carriage assembly from drive system.

Raise door manually approximately 3’- 4’ and release.

Door should remain stationary or move very slightly.

If door moves quickly, CONTACT A TRAINED DOOR SYSTEM TECHNICIAN.

Close the door.

Verify RED block in carriage is in the up position. (refer to page 19)

Operate door using remote or wall console.

Door will re-attach itself to carriage assembly.

3’ - 4’

Sectional Door

FIG. 6-1 Door balance

3’ - 4’

One-Piece Door

CONTACT REVERSE TEST (Monthly test)

The Force and Limit settings MUST be COMPLETED before testing. (See pages 6-7)

1.Test.

Open garage door using wall console.

Place a 2" x 4" board (laid flat) under center of garage door opening (Fig. 6-2).

Close garage door using wall console.

When door contacts board, the door must

stop (within 2 seconds) and reverse direction returning to open position.

2.Adjustment.

If the door:

Stops before it contacts the 2 x 4 board, it may simply be responding to an improperly set down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit.

Stops after contacting the 2 x 4 board and does not reverse, it may need an adjustment to the down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit.

Test again. Repeat as necessary until door

reverses upon contacting board.

FIG. 6-2 2 x 4 under center of door opening

18

©2011 The Genie Company

3/2011

Page 18
Image 18
Genie 4042 Sectional Door, One-Piece Door, 3’ - 4’, Safe-T-Beam STB SYSTEM CHECK, Contact A Trained Door System Technician