Genie 4042 manual Adjustment Guide - Force Settings, Force Level, Change Force Setting

Models: 4042

1 72
Download 72 pages 30.82 Kb
Page 23
Image 23
ADJUSTMENT GUIDE - FORCE SETTINGS

ADJUSTMENT GUIDE - FORCE SETTINGS

CHANGE FORCE SETTING CAUTION

Door closing force is FACTORY set and requires no adjustment for normal operation.

Never increase the door closing force to compensate for a damaged door or a binding door track.

Never adjust force to compensate for a broken door spring.

Perform monthly CONTACT REVERSE TEST as described on page 18.

Force settings are pre-programmed at the factory and "learned" during the Open/Close Limit settings steps. Some additional Force may be increased. For normal use, Force settings should not need adjustment with this unit.

However, conditions that might suggest an adjustment is necessary are;

Doors with very stiff weather seals.

Doors that start down, then STOP and reverse before they close.

Doors that start up, but STOP before they completely open.

FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM

CHANGE FORCE SETTING

Use this guide to ADJUST powerhead FORCE settings. NOTE: There are nine (9) force levels.

PROGRAM

1.Press on the powerhead and hold until both

SET

lights turn steady ON. Release button.

Lights go out and Round BLUE light comes ON.

2.Press Force Level three times, Round RED light comes ON.

PROGRAM

3.Press Manual background once to enter the Force Programming menu.SET The round LED will flash BLUE 3 times, then the current Force setting for UP force will display on the LEDs. See table below.

4.(If current UP Force setting is good, skip to Step

5.) Press Manual background to increase or Manual background to decrease UP Force

settings within the available range.

PROGRAM

5.Press SET to set UP Force level. The long LED will flash BLUE 3 times, then the current Force setting for DOWN force will display on the LEDs.

6.(If current DOWN Force setting is good, skip to Step 7.) Press Manual background to increase or Manual background to decrease

DOWN Force settings within the available range.

PROGRAM

7.Press SET to set DOWN Force level. Both LEDs flash BLUE to confirm.

Force Level

Powerhead LEDs

Round LED Long LED

Default LED display is the current Force setting

LED indicator colors

OFF,

Blue,

Purple,

Red

Force Level LED indicator colors

Force Level 1

Force Level 2

Force Level 3

Force Level 4

Force Level 5

Force Level 6

Force Level 7

Force Level 8

Force Level 9

Blue

OFF

ON

 

OFF

Blue

ON

 

Blue

Blue

ON

ON

Purple

OFF

ON

 

OFF

Purple

ON

 

Purple

Purple

ON

ON

Red

OFF

ON

 

OFF

Red

ON

 

Red

Red

ON

ON

©2011 The Genie Company

3/2011

23

Page 23
Image 23
Genie 4042 manual Adjustment Guide - Force Settings, Force Level, Change Force Setting, Powerhead LEDs Round LED Long LED