1 PROGRAMMING LIMITS & FORCE

6

1 PROGRAMMING LIMITS & FORCE

(Continuing from Installation Poster if provided)

SETTING & TESTING LIMITS AND FORCE

The OPEN (UP) and CLOSE (DOWN) Door Limit positions are controlled by making adjustments using the panel located on the bottom of the powerhead. Begin with Step 1 and continue through Step 10. Door Force is set during the final Open/Close cycle of these steps. The powerhead will automatically set door speed at slow if the distance between limits is less than 6 feet. Once Limits and Force are set DO NOT use theSETTING & TESTING LIMITS AND FORCEorA) CLOSE DOOR TRAVEL LIMITbuttons to open or close door.

NOTE: If bullet has NOT been engaged to WARNING

Make sure doorway is in view and clear of obstacles and people to avoid injury or damage to property.

DO NOT operate this unit from wall console before LIMITS and FORCE are set. Severe damage to the opener can occur.

The bullet MUST be engaged to carriage BEFORE setting limits. See Installation Poster (if provided) or refer to pages 11 and 19.

©2011 The Genie Company

A) CLOSE DOOR TRAVEL LIMIT

1 PRESS and HOLD

 

NOTE: If bullet has NOT been engaged to

PROGRAM

 

 

 

the carriage, do so now.

 

 

+

 

 

 

 

 

SET

Please note that there is a 30 second timeout

 

 

 

 

 

 

 

 

 

between each programming step.

 

 

 

 

A programming timeout during these steps has

 

 

 

 

occured when two RED flashing LEDs appear.

 

 

 

 

In the event of a timeout please restart at Step 1.

SEE BOTH

 

 

 

 

Blue LEDs

 

 

 

 

come ON

 

 

 

2

RELEASE

SEE round

Blue LED come ON

3PRESS and RELEASE

PROGRAM

+

 

 

SEE long Blue

LED come ON

If RED LED comes ON - STOP and

exit programming.

4

NOTE: If one or both LEDs come ON RED at this time, Limits programming menu was not entered properly. You must exit programming and restart.

To exit the programming function wait 30 seconds for the programming to time out.

5PRESS and HOLD until door is FULLY CLOSED then RELEASE

RAM

 

 

 

G

 

+

 

 

 

SE

 

 

 

 

PROGRAM

PRESS and the carriage, do so now.

RELEASE

3/2011

SET

SEE round Blue LED flashing

Watch door move

NOTE: You can start and stop door

movement using eitherPROGRAMManual background buttons until door is in correct open or closed position.

OT CE

Page 6
Image 6
Genie 4042 manual Programming Limits & Force, A Close Door Travel Limit, NOTE If bullet has NOT been engaged to