ADJUSTMENT GUIDE - SPEED SETTINGS

ADJUSTMENT GUIDE - SPEED SETTINGS

Speed settings are pre-programmed at the factory for the maximum speed. Speed settings should not need adjustment with this unit.

However, travel speed for the opener in both the open and close directions can be adjusted to slower speeds to minimize normal wear for heavy sectional doors.

NOTE: One piece doors are automatically set during Limits programming to the slowest speed and opener speed cannot be reset for one piece doors.

FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM

CHANGE SPEED SETTING

Use this guide to ADJUST powerhead SPEED settings.

There are three (3) Speed settings available on this unit for the open and close directions. Door type (one piece or sectional), door weight and balance, and condition of door components / track affect door speed. Speed adjustment may not be available for some installations depending on these factors.

PROGRAM

1.Press on the powerhead and hold until both

SET

lights turn steady ON. Release button.

Lights go out and Round BLUE light comes ON.

2.Press CHANGE SPEED SETTING two times and the Round BLUE and Long BLUE lights come ON.

PROGRAM

3.Press Speed Level once to enter the Speed Programming menu.SET The round LED will flash BLUE 3 times, then the current Speed setting for UP travel will display on the LEDs. See table below.

4.Press Powerhead LEDs to raise or Manual background to lower UP Speed settings withinManual backgroundthe available range.

NOTE: Faster door speeds may not be available.

PROGRAM

5.Press SET to set UP Speed level. The long LED will flash BLUE 3 times, then the current Speed setting for DOWN travel will display on the LEDs.

6.Press Manual background to raise or Manual background to lower DOWN Speed settings within the available range.

NOTE: Faster door speeds may not be available.

PROGRAM

7.Press SET to set DOWN Speed level. Both LEDs flash BLUE to confirm.

Speed Level

Powerhead LEDs

Round LED Long LED

Default LED display is the current Speed setting

Red Manual backgroundManual background Red

LED Speed indicator colors

Purple

Purple

Blue Manual backgroundManual background Blue

Speed Level LED indicator colors

MAXIMUM

MID

SLOW

Red

Red

ON

ON

Purple

Purple

ON

ON

Blue

Blue

ON

ON