8
©2011 The Genie Company
3/2011
CONTACT REVERSE TEST
The Force and Limit settings on the previous page MUST be COMPLETED before Contact Reverse testing.
1.Test.
•Open garage door using wall console.
–Place a 2" x 4" board (laid flat) under center of garage door opening.
•Close garage door using wall console.
•When door contacts board, the door must stop (within 2 seconds) and reverse direction returning to open position.
2.Adjustment.
•If the door:
–Stops before it contacts the 2 x 4 board, it may simply be responding to an improperly set down limit. Return to pages
–Stops after contacting the 2 x 4 board and does not reverse it may need an adjustment to the down limit. Return to pages
•Test again. Repeat as necessary until door reverses upon contacting board.
PRESS and RELEASE
2 | 3 |
DOOR OPENS
WARNING
A moving door can cause serious injury or death.
1.Keep people clear of opening while door is moving.
2.Do NOT allow children to play with opener, including wall console, remote, or wireless keypad.
3.During programming, door opener could begin to run, so stay away from moving door and its parts.
On Wall Console
1PRESS and RELEASE
4
Once the Contact Reverse Testing is complete continue with Programming Remotes on the next page.