Genie Z-34, Z-22 manual Function Tests, At the Ground Controls, Test Emergency Stop, Fundamentals

Models: Z-34, Z-22N Z-34, Z-22

1 36
Download 36 pages 63.66 Kb
Page 16
Image 16
Function Tests

Operator's Manual

Second Edition • Ninth Printing

 

 

 

 

Function Tests

Do Not Operate Unless:

3Always perform function tests prior to use. You learn and practice the principles of safe machine operation contained in this operator's manual.

1Avoid hazardous situations.

2Always perform a pre-operation inspection.

3Always perform function tests prior to use.

Know and understand the function tests before going on to the next section.

4Inspect the workplace.

5Only use the machine as it was intended.

Fundamentals

The function tests are designed to discover any malfunctions before the machine is put into service. The operator must follow the step-by-step instructions to test all machine functions.

A malfunctioning machine must never be used. If malfunctions are discovered, the machine must be tagged and removed from service. Repairs to the machine may only be made by a qualified service technician, according to the manufacturer’s specifications.

After repairs are completed, the operator must preform a pre-operation inspection and function tests again before putting the machine into service.

1Select a test area that is firm, level and free of obstruction.

At the Ground Controls

2Turn the key switch to ground control.

3Pull out the red Emergency Stop button to the on position.

Result: The beacon (if equipped) should flash.

Test Emergency Stop

4Push in the red Emergency Stop button to the off position.

Result: All ground and platform control functions should not operate.

5Pull out the red Emergency Stop button to the on position.

14

Genie Z-34/22 & Genie Z-34/22N

Part No.43654

Page 16
Image 16
Genie Z-34, Z-22 Function Tests, At the Ground Controls, Always perform function tests prior to use, Test Emergency Stop