LIGHTING INSTRUCTIONS

LIGHTING INSTRUCTIONS

1.Main Electrical power supply must always be switched on to the unit with the two burner switches in the off position (up) before lighting the heater.

2.Turn on main gas supply.

3.Verify that main electrical supply is switched on by checking the 115V AC power status display (Figures 32 and 33) indica- tor is on.

4.Burner selection: select low burn (front burner), medium burn (rear burner), or high burn (both burners). Low burn switch (Figure 32) controls the front burner only. Medium burn switch (Figure 33) controls the rear burner only. When both switches are down, they will activate both the low and medium burners, which is the high setting.

5.Heater operating LED sequence (Front Display Panel). Be- fore starting ensure that the power L.E.D (Figure 34A) is on and burner switches are off. Switch on the heater by engag- ing the low and medium burner switch, this will activate the pressure switch and the exhaust fan L.E.D (Figure 34E) will be on. Also the two burner L.E.D’s (Figure 34C and 34D) will start flashing for 35 seconds prior to ignition. Once both burners have ignited, the burner L.E.D’s will remain on. If you can’t see flame on the rear burner, but the burner L.E.D is on, then there will be flame there which will become more visible as the heater warms up. Once the heater warms up the low speed L.E.D (Figure 34F) will light and the convec- tion fan will blow warm air from the heater. As the heater

becomes warmer, the medium L.E.D (Figure 34G) will come on. When the heater has reached its highest operating tem- perature, all three L.E.D’s will light up and the convection fan will now be running at its high speed. Refer to page 30

-Fan Operation. When the heater has been running for some time, the water pump L.E.D (Figure 34B) may come on to signal that the pump has been activated. Refer to page 33

-Automatic Humidifier Operation.

Note: Three heat settings are available for operating your Mantis heater - low, medium and high.

a.Low setting (front burner only) - engage low burn switch only (Figure 32)

b.Medium setting (rear burner only) - engage medium burner switch only (Figure 33)

c.High setting (front and rear burners).

 

THERMOSTAT

 

C

D

E

 

 

 

 

 

 

DISPLAY MODE

 

 

 

 

 

BUTTON

 

 

 

H

 

Figure 31

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

F

FRONT

REAR

 

 

 

 

BURNER

BURNER

 

 

 

 

SWITCH

SWITCH

 

 

 

 

Figure 32

Figure 33

A

B

 

 

Figure 34

Caution: When switching from the front burner to the rear burner, be sure to activate the rear burner first, then turn off the front burner. When switching from rear burner to the front burner, be sure to activate the front burner first. Simple rule - always activate the desired burner first, then switch the other burner off. If it is switched the wrong way, the burner(s) will go out and the heater may need to be reset. Refer to page 38 - Resetting the Heater.