GPG1336090M43A* - Rise Range: 45° - 75°

BLOWER PERFORMANCE DATA - HEATING SPEEDS THREE PHASE

GPG1336090M43A* - Rise Range: 45° - 75°

Unit

 

LOW

 

 

MEDIUM

 

 

HIGH

 

Static

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

0.1

1100

342

1.57

62

1469

494

2.24

47

1655

604

2.67

NR

0.2

1037

335

1.52

66

1409

480

2.15

49

1579

587

2.68

NR

0.3

991

320

1.45

69

1327

459

2.08

52

1483

567

2.62

46

0.4

926

308

1.39

74

1257

442

2.00

55

1407

547

2.53

49

0.5

831

290

1.32

NR

1163

419

1.89

59

1329

522

2.44

52

0.6

773

279

1.25

NR

1094

398

1.80

63

1210

498

2.35

57

0.7

669

260

1.17

NR

942

363

1.65

73

1036

464

2.24

66

0.8

-

-

-

-

-

-

-

-

-

-

-

-

GPG1348090M43A* - Rise Range: 45° - 75°

Unit

 

T1 HEATING SPEED

 

 

T2 HEATING SPEED

 

 

T3 HEATING SPEED

 

Static

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

0.1

--------

--------

--------

--------

--------

--------

--------

--------

--------

--------

--------

--------

0.2

914

125

1.07

75

1,105

186

1.56

62

1,397

323

2.57

49

0.3

822

134

1.14

NR

1,024

193

1.60

67

1,346

331

2.67

51

0.4

733

140

1.20

NR

967

202

1.65

71

1,288

342

2.76

53

0.5

664

150

1.26

NR

884

214

1.76

NR

1,273

352

2.82

54

0.6

606

154

1.28

NR

816

220

1.75

NR

1,178

359

2.88

58

0.7

584

162

1.32

NR

769

230

1.85

NR

1,120

369

2.97

61

0.8

551

164

1.34

NR

698

236

1.89

NR

1,057

381

3.09

65

GPG1360090M43A* - Rise Range: 45° - 75°

Unit

 

LOW - T1

 

 

MEDIUM - T2

 

 

HIGH - T3

 

Static

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

0.1

1125

162

1.44

61

1466

315

2.67

47

1780

496

3.33

NR

0.2

1049

168

1.53

65

1384

322

2.74

50

1730

506

3.89

NR

0.3

1000

178

1.60

69

1347

329

2.78

51

1664

520

4.01

NR

0.4

910

184

1.64

75

1291

341

2.83

53

1608

526

4.03

NR

0.5

857

197

1.75

80

1237

350

2.9

55

1568

532

4.12

NR

0.6

809

201

1.83

85

1185

362

3.05

58

1515

546

4.14

45

0.7

739

207

1.86

93

1134

369

3.09

60

1477

552

4.18

46

0.8

703

218

1.96

97

1087

382

3.21

63

1422

562

4.23

48

GPG1360140M43A* - Rise Range: 45° - 75°

Unit

 

LOW - T1

 

 

MEDIUM - T2

 

 

HIGH - T3

 

Static

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

0.1

1125

162

1.44

NR

1466

315

2.67

NR

1780

496

3.33

59

0.2

1049

168

1.53

NR

1384

322

2.74

NR

1730

506

3.89

60

0.3

1000

178

1.6

NR

1347

329

2.78

NR

1664

520

4.01

63

0.4

910

184

1.64

NR

1291

341

2.83

NR

1608

526

4.03

65

0.5

857

197

1.75

NR

1237

350

2.9

NR

1568

532

4.12

67

0.6

809

201

1.83

NR

1185

362

3.05

NR

1515

546

4.14

69

0.7

739

207

1.86

NR

1134

369

3.09

NR

1477

552

4.18

71

0.8

703

218

1.96

NR

1087

382

3.21

NR

1422

562

4.23

72

NR = Heating Temperature Rise Not Recommended.