Goodman Mfg ACVC9/AMVC95, GCVC9/GMVC95 service manual Furnace Specifications

Models: Goodman 90%-95% Gas Furnace Units ACVC9/AMVC95 GCVC9/GMVC95

1 37
Download 37 pages 20.59 Kb
Page 16
Image 16

FURNACE SPECIFICATIONS

 

 

 

GMVC95

 

MODEL

GMVC950453BX*

GMVC950704CX*

GMVC950905CX*

GMVC950905DX*

GMVC951155DX*

 

 

 

 

 

 

 

 

 

Btuh Input (US) High Fire

46,000

69,000

92,000

92,000

 

115,000

 

Output (US) High Fire

44,300

66,900

88,800

88,800

 

111,100

 

Btuh Input (US) Low Fire

32,000

48,000

64,000

64,000

 

80,000

 

Output (US) Low Fire

30,800

46,400

61,700

61,700

 

77,400

 

A.F.U.E.

95%

95%

95%

95%

 

95%

 

 

 

 

 

 

 

 

 

Rated External Static (" w.c.)

.10 - .50

.10 - .50

.10 - .50

.10 - .50

 

.10 - .50

 

Temperature Rise (°F)

30 - 60

30 - 60

30 - 60

30 - 60

 

35 - 65

 

 

 

 

 

 

 

 

 

High Stage Pressure Switch Trip Point (" w.c.)

-0.75

-0.75

-1.70

-1.10

 

-1.10

 

Low Stage Pressure Switch Trip Point (" w.c.)

-0.30

-0.30

-0.60

-0.50

 

-0.50

 

Front Cover Pressure Switch Trip Point (" w.c)

-0.10

-0.10

-0.10

-0.10

 

-0.10

 

 

 

 

 

 

 

 

 

Blower Wheel (D" x W")

10 x 8

10 x 10

11 x 10

11 x 10

 

11 x 10

 

Blower Horsepower

1/2

3/4

1

1

 

1

 

 

 

 

 

 

 

 

 

Blower Speeds

 

Refer to airflow charts in this manual.

 

 

 

Max CFM @ 0.5 E.S.P.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply

115-60-1

115-60-1

115-60-1

115-60-1

 

115-60-1

 

Minimum Circuit Ampacity (MCA)

11.3

14.1

14.4

14.4

 

14.4

 

Maximum Overcurrent Device

15

15

15

15

 

15

 

 

 

 

 

 

 

 

 

Transformer (VA)

40

40

40

40

 

40

 

Heat Anticipator (Amps)

0.7

0.7

0.7

0.7

 

0.7

 

 

 

 

 

 

 

 

 

Primary Limit Setting (°F)

145

155

130

145

 

150

 

Auxiliary Limit Setting (°F)

150

190

120

180

 

200

 

Rollout Limit Setting (°F)

170

200

200

190

 

200

 

 

 

 

 

 

 

 

 

Fan Delay On Heating

30 secs.

30 secs.

30 secs.

30 secs.

 

30 secs.

 

Off Heating *

150 secs.

150 secs.

150 secs.

150 secs.

 

150 secs.

 

Fan Delay On Cooling

5 secs.

5 secs.

5 secs.

5 secs.

 

5 secs.

 

Off Cooling

45 secs.

45 secs.

45 secs.

45 secs.

 

45 secs.

 

Fan Delay On - Fan Only

5 secs.

5 secs.

5 secs.

5 secs.

 

5 secs.

 

 

 

 

 

 

 

 

 

Gas Supply Pressure (Natural/Propane) (" w.c.)

7 / 11

7 / 11

7 / 11

7 / 11

 

7 / 11

 

Manifold Pressure (Natural/Propane) High Stage (" w.c.)

3.5 / 10

3.5 / 10

3.5 /10

3.5 /10

 

3.5 /10

 

Manifold Pressure (Natural/Propane) Low Stage ("w.c.)

1.9 / 6.0

1.9 / 6.0

1.9 / 6.0

1.9 / 6.0

 

1.9 / 6.0

 

Orifice Size (Natural/Propane)

#43 / #55

#43 / #55

#43 / #55

#43 / #55

 

#43 / #55

 

Number of Burners

2

3

4

4

 

5

 

 

 

 

 

 

 

 

 

Vent Connector Diameter (inches)

2

2

2

2

 

2

 

Combustion Air Connector Diameter (inches)

2

2

2

2

 

2

 

 

 

 

 

 

 

 

 

Shipping Weight (lbs.)

133

157

172

172

 

184

 

 

 

 

 

 

 

 

* Off Heating - This fan delay timing is adjustable (90, 120, 150 or 180 seconds), 150 seconds as shipped.

1.These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation.

2.For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altitude.

3.The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times output.

4.Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.

16

Page 16
Image 16
Goodman Mfg ACVC9/AMVC95, GCVC9/GMVC95, Goodman 90%-95% Gas Furnace Units service manual Furnace Specifications