Goodman Mfg GCVC9/GMVC95 Furnace Specifications, GCVC90704CX, GCVC90905DX, GCVC91155DX

Models: Goodman 90%-95% Gas Furnace Units ACVC9/AMVC95 GCVC9/GMVC95

1 37
Download 37 pages 20.59 Kb
Page 18
Image 18

FURNACE SPECIFICATIONS

 

 

GCVC9

 

MODEL

 

GCVC90704CX*

GCVC90905DX*

GCVC91155DX*

 

 

 

 

 

 

 

 

 

Btuh Input (US) High Fire

 

69,000

92,000

115,000

 

 

Output (US) High Fire

 

65,300

86,500

109,000

 

 

Btuh Input (US) Low Fire

 

48,000

64,000

80,000

 

 

Output (US) Low Fire

 

45,000

60,100

77,400

 

 

A.F.U.E.

 

93.0%

92.0%

93%

 

 

 

 

 

 

 

 

 

Rated External Static (" w.c.)

 

.10 - .50

.10 - .50

.10 - .50

 

 

Temperature Rise (°F)

 

30 - 60

30 - 60

40 - 70

 

 

 

 

 

 

 

 

 

High Stage Pressure Switch Trip Point (" w.c.)

 

-0.55

-0.55

-0.55

 

 

Low Stage Pressure Switch Trip Point (" w.c.)

 

-0.20

-0.20

-0.20

 

 

Front Cover Pressure Switch Trip Point (" w.c)

 

-0.37

-0.37

-0.37

 

 

 

 

 

 

 

 

 

Blower Wheel (D" x W")

 

10 x 10

11 x 10

11 x 10

 

 

Blower Horsepower

 

3/4

1

1

 

 

 

 

 

 

 

 

 

Blower Speeds

 

Refer to airflow charts in this manual.

 

 

Max CFM @ 0.5 E.S.P.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply

 

115-60-1

115-60-1

115-60-1

 

 

Minimum Circuit Ampacity (MCA)

 

14.1

14.4

14.4

 

 

Maximum Overcurrent Device

 

15

15

15

 

 

 

 

 

 

 

 

 

Transformer (VA)

 

40

40

40

 

 

Heat Anticipator (Amps)

 

0.7

0.7

0.7

 

 

 

 

 

 

 

 

 

Primary Limit Setting (°F)

 

160

170

145

 

 

Auxiliary Limit Setting (°F)

 

220

180

180

 

 

Rollout Limit Setting (°F)

 

220

210

210

 

 

 

 

 

 

 

 

 

Fan Delay On Heating

 

30 secs.

30 secs.

30 secs.

 

 

Off Heating *

 

150 secs.

150 secs.

150 secs.

 

 

Fan Delay On Cooling

 

5 secs.

5 secs.

5 secs.

 

 

Off Cooling

 

45 secs.

45 secs.

45 secs.

 

 

Fan Delay On - Fan Only

 

5 secs.

5 secs.

5 secs.

 

 

 

 

 

 

 

 

 

Gas Supply Pressure (Natural/Propane) (" w.c.)

 

7 / 11

7 / 11

7 / 11

 

 

Manifold Pressure (Natural/Propane) High Stage (" w.c.)

 

3.5 / 10

3.5 /10

3.5 /10

 

 

Manifold Pressure (Natural/Propane) Low Stage ("w.c.)

 

1.9 / 6.0

1.9 / 6.0

1.9 / 6.0

 

 

Orifice Size (Natural/Propane)

 

#43 / #55

#43 / #55

#43 / #55

 

 

Number of Burners

 

3

4

5

 

 

 

 

 

 

 

 

 

Vent Connector Diameter (inches)

 

2

2

2

 

 

Combustion Air Connector Diameter (inches)

 

2

2

2

 

 

 

 

 

 

 

 

 

Shipping Weight (lbs.)

 

157

172

175

 

 

 

 

 

 

 

 

*Off Heating - This fan delay tim ing is adjustable (90, 120, 150 or 180 seconds), 150 seconds as shipped.

1.These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation.

2.For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altitude.

3.The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times output.

4.Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.

18

Page 18
Image 18
Goodman Mfg GCVC9/GMVC95, ACVC9/AMVC95 service manual Furnace Specifications, GCVC90704CX, GCVC90905DX, GCVC91155DX