Goodman Mfg GCVC9/GMVC95 GCVC9/ACVC9 Heating Speed Charts, Blower Performance Specifications

Models: Goodman 90%-95% Gas Furnace Units ACVC9/AMVC95 GCVC9/GMVC95

1 37
Download 37 pages 20.59 Kb
Page 27
Image 27
GCVC9/ACVC9 Heating Speed Charts

BLOWER PERFORMANCE SPECIFICATIONS

GCVC9/ACVC9 Heating Speed Charts

GCVC90704CX*

ACVC90704CX*

(Rise Range: 30 - 60°F)

Heating

 

Low Stage

High Stage

 

Adjust

CFM

CFM

Rise

Speed

Tap

at .1" - .5" w.c.

at .1" - .5" w.c.

(°F)

Tap

 

ESP

ESP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minus(-)

747

1,076

56

A

Normal

830

1,195

50

 

Plus (+)

913

1,315

46

 

Minus(-)

824

1,186

51

B

Normal

915

1,318

46

 

Plus (+)

1,007

1,449

42

 

Minus(-)

900

1,296

47

C

Normal

1,000

1,440

42

 

Plus (+)

1,100

1,584

38

 

Minus(-)

978

1,408

43

D

Normal

1,085

1,562

39

 

Plus (+)

1,194

1,719

35

 

 

 

 

 

GCVC90905DX*

ACVC90905DX*

(Rise Range: 30 - 60°F)

Heating

 

Low Stage

High Stage

 

Adjust

CFM

CFM

Rise

Speed

Tap

at .1" - .5" w.c.

at .1" - .5" w.c.

(°F)

Tap

 

ESP

ESP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minus(-)

999

1,439

56

A

Normal

1,110

1,598

50

 

Plus (+)

1,221

1,758

46

 

Minus(-)

1,067

1,536

52

B

Normal

1,185

1,706

47

 

Plus (+)

1,303

1,876

43

 

Minus(-)

1,134

1,633

49

C

Normal

1,260

1,814

44

 

Plus (+)

1,386

1,996

40

 

Minus(-)

1,202

1,730

46

D

Normal

1,335

1,922

42

 

Plus (+)

1,469

2,115

38

 

 

 

 

 

GCVC91155DX*

(Rise Range: 40 - 70°F)

Heating

 

Low Stage

High Stage

 

Adjust

CFM

CFM

Rise

Speed

Tap

at .1" - .5" w.c.

at .1" - .5" w.c.

(°F)

Tap

 

ESP

ESP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minus(-)

1,093

1,583

63

A

Normal

1,214

1,759

56

 

Plus (+)

1,335

1,935

51

 

Minus(-)

1,106

1,612

61

B

 

 

 

 

Normal

1,229

1,791

55

 

 

 

 

 

 

Plus (+)

1,352

1,970

50

 

 

 

 

 

 

Minus(-)

1,166

1,654

60

C

 

 

 

 

Normal

1,296

1,838

54

 

 

 

 

 

 

Plus (+)

1,426

2,022

49

 

Minus(-)

1,172

1,690

59

D

Normal

1,302

1,878

53

 

Plus (+)

1,432

2,066

48

 

 

 

 

 

1.Units are shipped without filter(s). CFM in chart is without filter(s).

2.All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed as needed. The first task is to determine the proper aiflow for the cooling system.

3.For most cooling applications, about 400 CFM per ton is desirable.

4.The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on rating plate.

5.Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling purposes only.

6.* Motor CFM minimum.

27

Page 27
Image 27
Goodman Mfg GCVC9/GMVC95, ACVC9/AMVC95 service manual GCVC9/ACVC9 Heating Speed Charts, Blower Performance Specifications