BLOWER PERFORMANCE SPECIFICATIONS
GMVC95/AMVC95 Continuous Fan Speed Chart
Model | Furnace Maxim um | Continuous Fan | |
CFM | Speed1,2 | ||
| |||
|
|
| |
GMVC950453BX* | 1400 | 420 | |
AMVC950453BX* | |||
|
| ||
|
|
| |
GMVC950704CX* | 1760 | 530 | |
AMVC950704CX* | |||
|
| ||
|
|
| |
GMVC950905CX* | 2200 | 660 | |
AMVC950905CX* | |||
|
| ||
|
|
| |
GMVC950905DX* | 2200 | 660 | |
AMVC950905DX* | |||
|
| ||
|
|
| |
GMVC951155DX* | 2200 | 660 | |
AMVC951155DX* | |||
|
|
1 Continuous fan speed is 30% of furnace m axim um CFM
2Three continuous fan s peeds are pos sible with the CTK01AA therm ostat: 30%, 50%, and 70% of furnace m axim um CFM
GCVC9/ACVC9 Continuous Fan Speed Chart
Model | Furnace Maximum | Continuous Fan | |
CFM | Speed1,2 | ||
| |||
|
|
| |
GCVC90704CX* | 1760 | 530 | |
ACVC90704CX* | |||
|
| ||
|
|
| |
GCVC90905DX* | 2200 | 660 | |
ACVC90905DX* | |||
|
| ||
|
|
| |
GCVC91155DX* | 2350 | 705 |
1Continuous fan speed is 30% of furnace maximum CFM
2Three continuous fan speeds are possible with the CTK01AA thermostat: 30%, 50%, and 70% of furnace maximum CFM.
GCVC95/ACVC95 Continuous Fan Speed Chart
Model | Furnace Maximum | Continuous Fan | |
CFM | Speed1,2 | ||
| |||
|
|
| |
GCVC950714CX* | 1760 | 530 | |
ACVC950714CX* | |||
|
| ||
|
|
| |
GCVC950915DX* | 2200 | 660 | |
ACVC950915DX* | |||
|
|
1Continuous fan speed is 30% of furnace maximum CFM
2Three continuous fan speeds are possible with the CTK01AA thermostat: 30%, 50%, and 70% of furnace maximum CFM.
1.Units are shipped without filter(s). CFM in chart is without filter(s).
2.All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed as needed. The first task is to determine the proper aiflow for the cooling system.
3.For most cooling applications, about 400 CFM per ton is desirable.
4.The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on rating plate.
5.Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling purposes only.
6.* Motor CFM minimum.