WIRING DIAGRAMS

*CVC9/*MVC95_AA

HIGH VOLTAGE!

DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO

DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

2

1

 

RD

WH

 

 

 

 

 

ID BLOWER TWO-STAGE PRESSURE

HIGH FIRE

JUNCTION

BK

 

 

 

 

 

 

 

24V HUM.

 

 

 

 

 

SWITCH ASSEMBLY

 

 

 

HOT

LOW FIRE

 

 

 

OR

PRESSURE

BOX

 

SURFACE

C

 

 

 

SWITC

 

 

PRESSURE

 

 

C

 

 

IGNITER

 

 

 

 

 

 

SWITCH

 

NO

 

NO

 

 

 

2 CIRCUIT

 

 

 

 

 

 

 

 

 

 

 

 

YL

 

 

CONNECTOR

 

 

 

 

OR

 

 

 

 

 

HI

3

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

TWO STAGE

C

2

BR

 

 

 

 

FLAME

 

GAS VALVE

 

 

 

 

 

C

 

SENSOR

PM

1

GY

 

GY

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

FRONT COVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESSURE SWITCH

 

 

 

GND

TO

 

115 VAC/ 1 Ø /60 HZ

 

POWER SUPPLY WITH

 

OVERCURRENT

 

PROTECTION DEVICE

 

L

 

WH

N

 

 

 

DISCONNECT

 

 

TO 115VAC / 1Ø /60 HZ POWER SUPPLY WITH

OVERCURRENT PROTECTION DEVICE

L

GND

N

R

 

 

 

 

DISCONNECT

 

MANUAL RESET ROLLOUT LIMIT

CONTROLS (SINGLE CONTROL ON

BL

45 kBTU)

 

PK

OR

AUTO RESET PRIMARY

 

 

LIMIT CONTROL

PU

 

 

3

WH

INDUCED

DRAFT

2

RD

BLOWER

1

BK

 

BURNER COMPARTMENT

GND

 

BR

OR

PU

BL

CHASSIS

 

GROUND

 

GN

DOOR

 

SWITCH

 

 

JUNCTION BOX

INDUCTOR COIL

 

70kBTU,90kBTU,

 

115kBTU M ODELS

 

ONLY

INDOOR

 

 

AIR

 

CIRCULATOR

 

BLWR

 

GN

LINE

NEUTRAL

 

BLOWER COMPARTMENT

 

 

 

 

 

MANUAL RESET

 

 

 

 

AUXILIARY

 

 

 

 

 

LIMIT CONTROL

 

 

1

24 V THERMOSTAT CONNE CTIONS

 

 

 

 

 

 

WH

O DEH

G W 1 W 2 Y 1 Y 2

C

2 R

1

RD

UM

 

SE E

 

 

BK

DIAGNO STIC

 

 

NOTE 5

 

LED'S

 

3

 

 

 

 

 

PU

YL

FUSE

24 V 3 A

BR

21 OR

PK

G

BR GY

YL

INTEGRATED CONTROL MODULE

EAC

ELECTRONIC

 

AIR CLEANER

 

IND HI

 

ID

 

BLWR

IND LO

HUM HUMIDIFIER

IGN

HOT SURFACE

IGNITER

FS

NEUTRAL

NEUTRAL

NEUTRAL

NEUTRAL

WH

 

2ND S TG DLY

 

 

RD

 

HEAT OFF

 

 

DELAY

1

DIP

UNUSED

SWITCHES

DEHUM

 

 

HEAT

2

 

DELAY

 

 

3

 

ADJUST

 

 

4

 

CO OL

 

 

 

 

B

1

 

 

2

 

FS

 

 

6

5

4

OR

9

8

7

OR

12

11

10

PK

15

14

13

GY

 

 

PU

BR

YL

 

 

 

 

 

 

 

 

GY

LINE

 

 

 

 

 

BK

 

 

 

 

FLAME SENSOR

 

 

 

LINE

 

115 VAC

NEUTRAL

 

 

FUSE 3 A

 

 

40 VA

 

R

TH (4)

 

TRANSFORMER

 

 

 

 

 

 

24 VAC

 

 

 

 

 

 

24V

Y1

TO +VDC

 

 

 

 

HLO (10)

 

 

THERMOSTAT

W 1

 

PS1 (2)

 

C

 

 

 

PSO (7)

 

 

 

 

 

 

 

LOW FIRE PRESS.

 

 

 

 

24V HUM.

SW ITCH

 

 

 

 

 

CONNECTIONS

 

 

 

NO

 

W 2

 

PRESS. S WTICH

 

 

 

TO

PS2 (12)

NO

 

 

Y2

M ICRO

HIGH FIRE

 

 

 

 

 

 

 

 

G

 

 

 

 

INTEGRATED CONTROL MODULE

WH

WH

RD

ECM MTR HARNESS

4

NEUTRAL

 

BL

 

 

GY

 

 

BK

4

 

3

BK

2

5

1

4

 

 

GR

 

3

 

2

PK

 

1

EAC

 

WH

WH

 

BK

BK

BK

 

WH

 

GND

BLOWER

 

 

COMPARTMENT

 

DOOR SWITCH

 

(OPEN WHEN

O

DEHUM

24V

 

HUM.

C

 

TO

R

TO

MICRO

HLI (1)

 

MVL (13)

NO

C FRONT COVER

MVH (14)

 

PRE SS. SWITCH

MVC (8)

 

 

 

 

 

GND (5)

 

 

 

 

 

TR (11)

 

 

 

GND

 

 

 

GND (4)

 

 

 

 

 

+ VDC (1)

 

 

 

 

 

INDOOR

 

RX (2)

 

AIR

 

TX (3)

CIRCULATOR

BLWR

 

PM

HI

C

GAS

VALVE

CIRCULATOR BLOWER

 

 

 

DOOR OPEN)

INDUCTOR COIL

70kBTU,90kBTU,

 

115kBTU M ODELS

 

 

ONLY

 

INTEGRATED CONTROL MODULE

HUMIDIFIER

NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

2.MANUFACTURER'S SPECIFIED REPLACEMENT PAR TS MUST BE USED W HEN SERVICING.

3.IF ANY OF THE O RIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATER IAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY.

4.UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

5.TO RECALL THE LAST 6 FAULT S, MOST RECENT TO LEAST RECENT, DE PRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STA NDBY (NO THERMOSTAT INPUTS)

0140F00530

REV. B

COLOR CODES: PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK

LOW VOLTAGE (24V)

LOW VOLTAGE FIELD

HI VOLTAGE (115V)

HI VOLTAGE FIELD

JUNCTION

TERMINAL

INTERNAL TO

INTEGRATED CONTROL

PLUG CONNECTION

EQUIPMENT GND

FIELD GND FIELD SPLICE SWITCH (TEMP.)

IGNITER SWITCH (PRESS.)

OVERCURRENT PROT. DEVICE

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

34

Page 34
Image 34
Goodman Mfg ACVC9/AMVC95, GCVC9/GMVC95, Goodman 90%-95% Gas Furnace Units Wiring Diagrams CVC9/*MVC95AA, 24V HUM

Goodman 90%-95% Gas Furnace Units, ACVC9/AMVC95, GCVC9/GMVC95 specifications

Goodman Manufacturing is a prominent name in the HVAC industry, known for providing energy-efficient solutions that cater to both residential and commercial environments. Among its offerings, the Goodman GCVC9/GMVC95 and ACVC9/AMVC95 models stand out as top-tier gas furnace units, with efficiency ratings between 90% and 95%. These furnaces provide an excellent balance of performance, reliability, and affordability.

The GCVC9 and GMVC95 gas furnace units are designed with advanced features that ensure optimal heating and comfort. One of the key characteristics of these models is their energy efficiency. With Annual Fuel Utilization Efficiency (AFUE) ratings of up to 95%, these furnaces convert nearly all the fuel they consume into heat, resulting in significant cost savings on energy bills. This makes them an ideal choice for homeowners looking to reduce their carbon footprint while maintaining a comfortable indoor environment.

These units are equipped with a two-stage gas valve and a variable-speed blower motor. The two-stage gas valve allows for precise temperature control by providing two levels of heating output, ensuring that the furnace runs at lower capacities during milder conditions and ramping up when more heat is needed. The variable-speed blower motor enhances comfort by providing consistent airflow, reducing temperature fluctuations, and operating more quietly than single-speed motors.

Another notable feature is the firing system, which utilizes a hot surface igniter for reliable operation. This technology enhances safety and performance, eliminating the need for a pilot light and minimizing gas waste. Additionally, both models are designed for easy installation and maintenance, with features like a compact design and convenient access to internal components.

Durability is also a hallmark of Goodman furnaces. The units are constructed with high-quality materials, including a heavy-gauge steel cabinet and a durable powder-coated finish to resist corrosion. Furthermore, Goodman offers exceptional warranties, including a lifetime heat exchanger warranty, providing peace of mind for homeowners.

In conclusion, the Goodman GCVC9/GMVC95 and ACVC9/AMVC95 gas furnace units are engineered for efficient heating with advanced technologies that enhance performance and comfort. Their high AFUE ratings, reliable ignition system, and durable construction make them excellent choices for anyone looking to invest in a reliable heating solution. With Goodman at the helm, homeowners can enjoy efficient heating without compromising on comfort or cost.