Goodman Mfg SS-CPH90-150 dimensions Expanded Heating Data, Product Specifications

Models: SS-CPH90-150

1 36
Download 36 pages 26.92 Kb
Page 7
Image 7
Expanded Heating Data

Product Specifications

Expanded Heating Data

CPH090

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

114.4

108.3

101.9

95.3

91.0

88.2

81.9

75.5

70.5

65.0

59.9

56.6

54.5

48.9

43.3

37.8

32.2

26.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T/R

35.3

33.4

31.5

29.4

28.1

27.2

25.3

23.3

21.7

20.1

18.5

17.5

16.8

15.1

13.4

11.7

9.9

8.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

8.22

8.06

7.91

7.75

7.66

7.59

7.44

7.29

6.93

6.78

6.63

6.54

6.49

6.33

6.19

6.04

5.89

5.74

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

30.2

28.4

26.9

25.6

24.9

24.5

23.4

22.5

21.8

21.1

20.3

20.0

19.8

19.1

18.2

17.4

16.5

15.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COP

4.07

3.93

3.77

3.60

3.48

3.40

3.22

3.03

2.98

2.81

2.64

2.53

2.46

2.26

2.05

1.83

1.60

1.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI PR

424

406

390

373

365

358

344

330

316

302

290

283

278

267

257

246

238

229

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO PR

134

124

117

107

101

97

89

80

72

64

56

52

51

43

37

31

27

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPH102

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

128.2

121.4

114.2

106.8

102.0

98.8

91.8

84.7

69.2

63.8

58.8

55.5

53.4

48.0

42.5

37.1

31.6

25.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T/R

34.9

33.1

31.1

29.1

27.8

26.9

25.0

23.1

18.8

17.4

16.0

15.1

14.6

13.1

11.6

10.1

8.6

7.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

9.34

9.17

8.99

8.82

8.72

8.64

8.48

8.30

7.8

7.7

7.5

7.4

7.3

7.2

7.0

6.9

6.7

6.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

37.6

35.2

33.2

31.6

30.6

30.1

28.7

27.5

26.6

25.6

24.6

24.2

23.9

23.0

21.8

20.8

19.6

18.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COP

4.02

3.87

3.72

3.54

3.42

3.35

3.17

2.98

2.6

2.4

2.3

2.2

2.1

2.0

1.8

1.6

1.4

1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER

13.7

13.2

12.7

12.1

11.7

11.4

10.8

10.2

8.8

8.3

7.8

7.5

7.3

6.7

6.1

5.4

4.7

4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI PR

419

401

386

369

360

354

340

326

312.5

298.4

286.5

279.7

274.6

264.2

254.1

243.6

235.0

226.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO PR

136

126

118

108

103

99

91

81

73

65

57

53

51

43

37

32

28

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPH120

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

150.8

142.8

134.4

125.6

120.0

116.3

108.0

99.6

87.7

81.0

74.6

70.4

67.8

60.8

53.9

47.0

40.1

32.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T/R

34.9

33.1

31.1

29.1

27.8

26.9

25.0

23.1

20.3

18.7

17.3

16.3

15.7

14.1

12.5

10.9

9.3

7.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

10.70

10.50

10.31

10.11

10.00

9.92

9.73

9.54

8.65

8.47

8.30

8.20

8.13

7.95

7.78

7.61

7.44

7.27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

41.3

38.9

36.9

35.3

34.3

33.8

32.4

31.2

30.2

29.3

28.3

27.8

27.6

26.6

25.4

24.4

23.3

21.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COP

4.13

3.98

3.82

3.64

3.51

3.43

3.25

3.06

2.97

2.80

2.63

2.51

2.44

2.24

2.03

1.81

1.58

1.32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI PR

439

421

405

387

378

371

356

342

328

313

301

293

288

277

266

256

246

238

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO PR

133

123

115

106

100

96

89

79

71

64

56

52

50

42

37

31

27

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPH150

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

188.6

178.5

168.0

157.1

150.0

145.4

135.0

124.5

102.2

94.3

86.8

82.0

79.0

70.8

62.8

54.8

46.7

38.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T/R

41.6

39.4

37.0

34.6

33.1

32.0

29.8

27.4

22.5

20.8

19.1

18.1

17.4

15.6

13.8

12.1

10.3

8.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

14.59

14.30

14.00

13.71

13.54

13.42

13.13

12.84

12.18

11.89

11.62

11.45

11.34

11.05

10.78

10.50

10.21

9.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AMPS

58.8

55.0

52.0

49.3

47.8

47.0

44.8

42.9

41.4

39.9

38.3

37.6

37.2

35.7

33.8

32.3

30.4

28.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COP

3.78

3.65

3.51

3.35

3.24

3.17

3.01

2.84

2.46

2.32

2.19

2.10

2.04

1.88

1.71

1.53

1.34

1.13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI PR

471

452

434

415

405

398

382

367

351

336

322

315

309

297

286

274

264

255

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO PR

129

120

113

103

98

94

86

77

69

62

54

51

49

41

36

30

26

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

High pressure measured at liquid line access fitting; Low pressure measured at compressor suction access fitting.

Amps = unit amps (comp.+fans) kW = Total system power

SS-CPH90-150

www.goodmanmfg.com

7

Page 7
Image 7
Goodman Mfg SS-CPH90-150 dimensions Expanded Heating Data, Product Specifications

FAQ

What information is included in the product specifications for Goodman Mfg models SS-CPH90-150?

The product specifications include details on outdoor ambient temperature, capacity, power, and pressure.

Where can I find the heating data for Goodman Mfg models SS-CPH90-150?

The expanded heating data for these models can be found in the official manual on the Goodman Mfg website.

Is the outdoor ambient temperature data listed for specific temperature ranges?

Yes, the outdoor ambient temperature data is listed for temperature ranges from 65 degrees to -10 degrees.