SERVICING

WARNING

Line Voltage now present.

4

3

OHMMETER

5

1

2

TESTING FAN RELAY

4.Using an ohmmeter, test between 2 and 4 - should read continuous . Test between 5 and 6 - should read open.

5.If not as above, replace the relay.

S-10 COPELAND COMFORT ALERT™

DIAGNOSTICS

Applies to ASX /ASZ and DSX/DSZ units

Comfort Alert™ is self-contained with no required external sensors and is designed to install directly into the electrical box of any residential condensing unit that has a Copeland Scroll™ compressor inside.

Once attached, Comfort Alert™ provides around-the-clock monitoring for common electrical problems, compressor defects and broad system faults. If a glitch is detected, an LED indicator flashes the proper alert codes to help you quickly pinpoint the problem. See Diagnostic Table on following page.)

39

Page 39
Image 39
Goodmans SSZ, GSZ, ASZ, SSX, ASX, DSZ, DSX, GSX manual Copeland Comfort Alert Diagnostics, Testing FAN Relay