Pressure Relief Procedure

Pressure Relief Procedure

Models with Advanced Display Module

Models with Standard Display Module

1.Place a waste container below the dispense valve.

2.Navigate to the Manual screen.

3.Press the Open Dispense Valve button on the Man- ual screen to relieve chemical pressure.

4.Press the Machine Disable Mode button ( ).

5.Press the system air pressure relief switch down to stop air supply and to vent air pressure in the machine. It is the yellow tab at the left, rear of the machine. The hole in the tab should be visible.

6.If necessary, run a lock through the hole to lock the tab in place. This prevents the system air pressure from being inadvertently enabled.

With the machine in an idle state:

1.If the machine pistons are not fully retracted, retract

the pistons by pressing in the M1 screen. See manual 3A0429 for more information.

2.Manually open the dispense valve by pressing the

third M1 soft key until the “” ICON is shown in the Current DV field. See manual 3A0429 for more infor- mation.

3.Press the system air pressure relief switch down to stop air supply and to vent air pressure in the machine. It is the yellow tab at the left, rear of the machine. The hole in the tab should be visible.

4.If necessary, run a lock through the hole to lock the tab in place. This prevents the system air pressure from being inadvertently enabled.

18

312394V

Page 18
Image 18
Graco 312394V important safety instructions Pressure Relief Procedure