Image 23

Shutdown

Shutdown

If the machine is to remain idle for an extended period of time, perform the following steps.

1.Place a waste container below the dispense valve.

2.If installed, remove static mixer from the end of the dispense valve.

3.Place a container below the dispense valve and activate a small shot to flush mixed material out of the valve.

4.Relieve pressure. See Pressure Relief Procedure on page 18.

5.With a clean rag and cotton swabs, clean the end of the dispense valve.

6.Install nightcap on the dispense valve.

312394V