Graco 3A1214B important safety instructions Safe Range cold

Models: 3A1214B

1 28
Download 28 pages 52.03 Kb
Page 21
Image 21

3.Check engine oil level. Add SAE 10W-30 (summer) or 5W-20 (winter), if necessary.

(cold)

ti16447a

4.Fill fuel tank.

5.Check hydraulic oil level. Add only Graco Hydraulic Oil, ISO 46 169236 (5 gallon/18.9 liter) or 207428 (1 gallon/3.8 liter). Hydraulic tank capacity is approxi- mately 4.0 gallons (15.14 liters).

ti5243a

Safe Range (cold)

6.Check oil level in compressor. NOTE: If red dot is visible, add oil.

ti16789a

7.Verify all hose/fitting connections are tight.

8.Turn hydraulic lines to closed position.

ti15838a

Operation

9.Turn pump lever by guns clockwise 1/4 turn to OFF position.

ti15953a

10.Place suction tube and drain tube in grounded metal pail partially filled with flushing fluid. Attach ground wire to pail and to earth ground.

ti16547a

11. Turn prime valve down.

ti16552a

12.Install clean inlet strainer. NOTE: There must be a minimum of 0.5 in. between bottom of strainer and suction tube.

ti16553a

0.5 in.

13.Turn pressure control counterclockwise to lowest pressure.

ti16919a

3A1214B

21

Page 21