3.Check engine oil level. Add SAE
(cold)
ti16447a
4.Fill fuel tank.
5.Check hydraulic oil level. Add only Graco Hydraulic Oil, ISO 46 169236 (5 gallon/18.9 liter) or 207428 (1 gallon/3.8 liter). Hydraulic tank capacity is approxi- mately 4.0 gallons (15.14 liters).
ti5243a | Safe Range (cold) |
6.Check oil level in compressor. NOTE: If red dot is visible, add oil.
ti16789a
7.Verify all hose/fitting connections are tight.
8.Turn hydraulic lines to closed position.
ti15838a
Operation
9.Turn pump lever by guns clockwise 1/4 turn to OFF position.
ti15953a
10.Place suction tube and drain tube in grounded metal pail partially filled with flushing fluid. Attach ground wire to pail and to earth ground.
ti16547a
11. Turn prime valve down.
ti16552a
12.Install clean inlet strainer. NOTE: There must be a minimum of 0.5 in. between bottom of strainer and suction tube.
ti16553a
0.5 in.
13.Turn pressure control counterclockwise to lowest pressure.
ti16919a
3A1214B | 21 |