HandyTone-386 User Manual Grandstream Networks, Inc.
23
6.2.3 Advanced Configuration and FXS po r t s Parameters
To login to the Advanced Setting and FXS port configuration pages, administrator password is
required. The default administrator password is “admin”. User can change the admi nistrator password
here. The password is case sensitive and the maximum length is 25 characters.
Advanced Settings Page:
Grandstream Device Configuration
STATUS BASIC
SETTINGS ADVANCED
SETTINGS FXS
PORT1 FXS
PORT2
Admin Password: (purposely not displayed for security
protection)
Home NPA:
L
ayer 3 QoS: 48 (Diff-Serv or Precedence value)
L
ayer 2 QoS: 802.1Q/VLAN Tag 0 802.1p priority value 0(0-7)
STUN server is : stun.sipserver.com (URI or IP:port)
keep-alive interval: 20 (in seconds, default 20 seconds)
Use NAT IP: (used in SIP/SDP message if specified)
F
irmware Upgrade and
P
rovisioning: Upgrade Via TFTP HTTP
Firmware Server Path: fm.grandstream.com/gs
Config Server Path: fm.grandstream.com/gs
Firmware File Prefix: Firmware File Postfix:
Config File Prefix: Config File Postfix:
Automatic Upgrade:
No Yes, check fo r upgrade every 1008
0
minutes (default 7
days)
Always Check for New Firmware
Check New Firmware only when F/W pre/suffix changes