SECTION 3: CIRCUIT REQUIREMENTS
Amperage Draw
The Model G0527 has three motors that are wired to operate on a 220V
Sanding Drum Motor | 30 | Amps |
Conveyor Feed Motor | 3.8 | Amps |
Elevation Motor | 3 | Amps |
Figure 1. Locking shut-off lever.
Circuit Breaker
Use the following guidelines when choosing a cir- cuit breaker (circuit breakers rated any higher are not adequate to protect the circuit):
Circuit Breaker | 40 Amp, 2 Pole | |
|
|
|
|
|
|
|
|
|
|
|
|
Connection Type
Because of the high amperage draw from this machine, we recommend that you hardwire it directly to your circuit breaker and install a lock- ing
Circuit Capacity
Always check to see if the wires in your circuit are capable of handling the amperage load from your machine. If you are unsure, consult a qualified electrician.
If you operate this machine on any circuit that is already close to its capacity, it might blow a fuse or trip a circuit breaker. However, if an unusual load does not exist and a power failure still occurs, contact a qualified electrician or our Service Department at (570)
G0527 18" Wide Belt Sander |