SECTION 2: CIRCUIT REQUIREMENTS

Operation

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The motor for your machine may draw the follow- ing amps at maximum load.

G0605X @ 220V

23 Amps

G0606X @ 220V

19 Amps

G0606X @ 440V*

10 Amps

Circuit Requirements

You MUST connect your machine to a grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing cir- cuit with one of higher amperage without consult- ing a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to con- nect your machine to a shared circuit, consult a qualified electrician.

G0605X @ 220V

30 Amps

G0605X @ 220V

30 Amps

G0606X @ 440V*

15 Amps

*To run on 440V, you must rewire the motor, switch the transformer fuse from 220V to 440V, and change the thermal overload relay from 22 to 11 Amps. Refer to the wiring dia- gram on Page 59 for wiring details.

-12-

Plug Type

The cord set enclosed does not have a plug as the style of plug you will require depends upon the type of service you currently have or plan to install. We recommend using the following plugs for your machine on a dedicated circuit only (see Figures 2–4for examples):

G0605X @220V Single-Phase.................. L6-30

G0606X @220V 3-Phase.........................L15-30

G0606X @440V 3-Phs... Power Shut-Off Switch

Figure 2. NEMA L6-30 plug and receptacle.

Figure 3. NEMA L15-30 plug and receptacle.

G0605X/G0606X Extreme Series 12" Table Saw

Page 14
Image 14
Grizzly G0605X, G0606X owner manual Circuit Requirements, Operation, Amperage Draw, Plug Type