Symptom

Possible Cause

Possible Solution

Machine has vibra-

1.

Motor or component is loose.

1.

Inspect/replace stripped or damaged bolts/nuts, and

tion or noisy opera-

 

 

 

re-tighten with thread locking fluid.

tion.

2.

Flat belt worn or loose.

2.

Inspect/replace flat belt with new one (refer to Page

 

 

 

 

 

47).

 

3.

Motor fan is rubbing on fan cover.

3.

Replace dented fan cover; replace loose/damaged

 

 

 

 

fan.

 

4.

Pulley is loose.

4.

Realign/replace shaft, pulley, set screw, and key as

 

 

 

 

required.

 

5.

Machine sits unevenly on floor.

5.

Relocate/shim machine.

 

6.

Arbor bearings are at fault.

6.

Replace arbor housing bearings; replace arbor.

 

7.

Arbor pulley is loose.

7.

Retighten/replace arbor pulley with shaft and thread

 

 

 

 

locking liquid.

 

8.

Workpiece is loose.

8.

Use the correct holding fixture and reclamp

 

 

 

 

workpiece.

 

9.

Motor bearings are at fault.

9.

Test by rotating shaft; rotational grinding/loose shaft

 

 

 

 

requires bearing replacement.

 

10. Blade is at fault.

10. Replace warped, bent, or twisted blade; resharpen

 

 

 

 

dull blade.

 

11. Loose arbor nut

11. Tighten the arbor nut.

 

12. Centrifugal switch (single-phase).

12. Replace centrifugal switch.

 

 

 

 

Table Saw Operations

 

 

Symptom

 

Possible Cause

Possible Solution

Blade is not aligned

1.

Blade is warped.

1.

Replace blade (Page 22).

with miter slot

or

2.

Table top is not parallel to blade.

2.

Make table parallel to blade (Page 51).

fence.

 

 

3.

Fence is not parallel to blade.

3.

Make fence parallel to blade (Page 54).

 

 

 

 

 

 

 

 

 

Blade

does not

1.

90° stop bolt is out of adjustment.

1.

Adjust 90° stop bolt (Page 49).

reach 90°.

 

2.

Sawdust loaded up on positive stop.

2.

Clean sawdust off positive stop.

 

 

 

 

 

 

 

Blade

hits insert

at

1.

45° stop bolt is out of adjustment.

1.

Adjust 45° stop bolt (Page 49).

45°.

 

 

2.

Hole in insert is inadequate.

2.

File or mill the hole in the insert.

 

 

 

3.

Table out of alignment.

3.

Align blade to the table (Page 51).

 

 

 

4.

Blade position is incorrect.

4.

Adjust blade position.

 

 

 

 

 

 

 

Board

binds

or

1.

Dull blade.

1.

Replace blade.

burns when feeding

2.

Blade is warped.

2.

Replace blade (Page 22).

through tablesaw.

 

3.

Fence is not parallel to blade.

3.

Make fence parallel to blade (Page 54).

 

 

 

 

 

 

4.

Table top is not parallel to blade.

4.

Make table parallel to blade (Page 51).

 

 

 

 

 

 

 

-46-

G0605X/G0606X Extreme Series 12" Table Saw

Page 48
Image 48
Grizzly G0605X, G0606X owner manual Table Saw Operations