Symptom

 

Possible Cause

Possible Solution

 

 

 

Machine stalls or is

11. Contactor not getting energized or has poor

11. Test for power on all legs and contactor operation.

overloaded.

 

 

contacts.

 

Replace if at fault.

 

 

12. Motor has overheated.

12. Let cool, Clean off motor, and reduce workload.

 

 

13. Spindle rotation switch at fault.

13. Turn switch to FWD/REV; replace bad switch.

 

 

14. Motor is at fault.

14. Test/repair/replace.

 

 

15. Frequency drive at fault.

15. Test/replace.

 

 

 

 

 

 

Machine

has

1.

Chuck or cutter is at fault.

1.

Replace out-of-round chuck; replace/resharpen

vibration or

noisy

 

 

 

cutter; use appropriate feed rate and cutting RPM.

operation.

 

2.

Workpiece alignment is poor.

2.

Eliminate workpiece binding; use vise or clamps as

 

 

 

 

 

 

 

required for workpiece alignment control.

 

 

3.

Motor or component is loose.

3.

Inspect/replace stripped or damaged bolts/nuts, and

 

 

 

 

 

re-tighten with thread locking fluid.

 

 

4.

Pulley is loose.

4.

Realign/replace shaft, pulley, setscrew, and key as

 

 

 

 

 

required.

 

 

5.

Motor mount loose/broken.

5.

Tighten/replace.

 

 

6.

Machine is incorrectly mounted or sits

6.

Tighten/replace anchor studs in floor; relocate/shim

 

 

 

unevenly.

 

machine.

 

 

7.

Motor fan is rubbing on fan cover.

7.

Replace dented fan cover; replace loose/damaged

 

 

 

 

 

fan.

 

 

8.

Motor bearings are at fault.

8.

Test by rotating shaft; rotational grinding/loose shaft

 

 

 

 

 

requires bearing replacement.

 

 

9.

Gearbox is at fault.

9.

Rebuild gearbox for bad gear(s)/bearing(s).

 

 

 

 

 

 