Reasons

 

 

Removing methods

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Fuse is broken

 

 

1.

Check if there is short circuit and

 

 

 

 

2.

The contact of plug, socket, and cable

solve it, if not, change capable fuse

 

 

 

 

is not good. Cable broken.

 

2.

Check and connect tightly, or

 

 

 

 

3.

The voltage is too low, 10-15% less

change.

 

 

 

 

than rated voltage

 

 

3.

Use till voltage rises to rated

 

 

 

 

4. The knob of temperature controller is at

value or attach a stabilizer.

 

 

 

 

“rest” position.

 

 

4.

Rotate the knob to wanted

 

Compressor

5.

The temperature controller is out of

position for suitable temperature.

 

can

not

be

order.

 

 

 

5.

Change the controller.

 

started

 

6. Starting relay or thermal protection unit

6.

Change starting relay or thermal

 

 

 

 

is out of order or broken.

 

 

 

 

 

7.

Wire broken of motor starting coil or

protection unit.

 

 

 

 

operation coil.

 

 

7.

Measure using R×1 position of

 

 

 

 

8.

The compressor motor is burned or

avometer, if there is wire broken,

 

 

 

 

change compressor.

 

 

 

 

rotator and stator are blocked to dead.

 

8.

Change compressor.

 

 

 

 

9.

There is leakage of high-pressure gas

 

 

 

 

 

 

valve or the shaft is embraced to dead.

 

9.

Change compressor.

 

 

 

 

1.

The distance between temperatures

 

1 Adjust and make it close to

 

 

 

 

sensing tube of temp. Controller and

 

evaporator cover.

 

 

 

 

evaporator are too big.

 

 

 

 

Compressor

2.

The temperature controller is out of

 

2.Change the temperature

 

order.

 

 

 

controller.

 

starts

 

too

 

 

 

 

 

3.

Food stuffs in the freezer too much,

 

3.Reduce them.

 

frequent,

 

door opens too frequent and open time

 

 

 

operation

 

 

 

 

 

too long.

 

 

 

 

 

time too long,

 

 

 

 

 

4.

The environment temperature is too

 

4.Put the freezer to suitable place

 

but

 

 

high, humidity too high, airflow is

 

and make air circulate well.

 

temperature

 

 

impeded.

 

 

 

 

 

drop

 

in

 

 

 

 

 

 

5.

The frost layer at the evaporator is too

5.Remove frost regularly.

 

freezer is too

 

slow

 

 

thick.

 

 

 

 

 

 

 

 

6.

The refrigerant is insufficient or

 

6.Check or supplement refrigerant.

 

 

 

 

 

 

 

 

 

leakage.

 

 

 

 

 

 

 

 

7.

Compressor efficiency is reduced.

 

7.Change compressor.

 

 

 

 

8.

The drying filter is blocked.

 

8.Change new drying filter.

 

Compressor

1.The knob of temperature controller has

1.

Change the position to

 

been set to “over cooling” position.

 

 

moderate.

 

runs

without

2.The

contacting point of temperature

2.

Repair or change.

 

stop,

 

 

controller is adhered.

 

 

 

 

 

temperature

3.The

temperature

sensing probe

of

3.

Adjust to suitable position,

 

in freezer

is

controller is not placed well, and causes

 

normally contact tightly with

 

too low

 

maladjustment

 

 

 

evaporator cover.

 

 

 

 

4.Compressor efficiency reduced.

 

4.Change compressor.

 

Compressor

1.

Voltage is too low.

 

1.

Supplement a stabilizer, adjust

 

buzzes and

 

to rated value.

 

 

 

 

 

 

 

cannot be

 

2.

Starting relay out of order.

 

2.

Change starting relay.

 

started,

 

 

3.

Change compressor.

 

 

3.

The starting coil

of starting motor

is

 

thermal

 

broken.

 

 

 

 

 

protection

 

 

 

4.The shaft and piston in the

 

 

4.

Compressor does not run.

 

 

unit jump

 

 

compressor is blocked, please

 

 

 

 

 

 

 

24