(7) Cooling speed

sensing parts of thermometers, and put the bottom end of gauze into distilled water) under the blowing of wind with the speed of 2.5-3m/s. Record the temperature of dry bulb thermometer, and calculate the relative humidity using the <<Relative humidity referring table for environment test>> GB6999-86.

(7) Cooling speed

Leave the freezer at test room, room temperature is 32 , the inner temperature of freezer gets balance with room temperature (temperature difference +-1K). Close freezer door and let the freezer running continuously. Record the time needed for storage temperature tm to reach

tm(max) in accordance with table 13-3, cooling temperature tm to reach +14 , and the time the freezing temperature reaches the corresponding star level. According to standard, 250L below freezer will not exceed 2h; 250L-500L freezers will not exceed 3h.

(8) Freezing ability

The freezing ability of freezer shall not be less than 90% of rated ability.

MAINTENANCE SERVICE AND TROUBLE SHOOTING

Maintenance Service and Trouble Shooting

(9) Electricity consumption

Leave the freezer at test room, climate temperatures are: SN, N, and ST