The

fan

1.

Check if any connection has come off.

1. Change the fan.

 

doesn’t run

2.

Check is the fan is burned.

2. Change the fan.

 

 

 

 

 

 

 

 

Electricity

 

1.

The service time is too long.

1.

Change temperature controller.

 

leakage

of

 

 

 

 

2. Use brush to remove dust.

 

temperature

2.

The environment is too dirty.

3.

Make the temperature dry and

 

controller

 

3.

Humidity is too high.

 

control the environment humidity.

 

Temperature

1.

There is

leakage

of temperature

 

 

 

sensing medium.

 

 

 

 

controller

out

 

Change temperature controller.

 

2.

Damage of

cam of

contacting point

 

of order

 

spring, etc.

 

 

 

 

 

 

 

 

 

 

 

 

The probe of

 

 

 

 

 

 

 

temperature

 

 

 

 

 

 

 

sensing

tube

It

has not been mounted to position or

 

 

 

doesn’t

 

Mount it again.

 

contact

 

changed during transportation.

 

 

 

 

 

 

 

 

 

 

 

evaporator

 

 

 

 

 

 

 

well

 

 

 

 

 

 

 

12.1.12 Procedure for fan change

(1)Switch off power and open the fan protection cover.

(2)Remove the fan bolts by using fork wrench or universal tool.

(3)Loose the fan blade and take it out.

(4)Take the fan out from the space between compressor and tubes.

(5)Mount new fan from the space between the compressor and tubes, put blade onto position and secure it by using a fork wrench or universal tool.

(6)Make a test run; check if the operation is normal, if there is any blocking of blade.

(7)Make sure not to bend or damage tubing during removal and installation.

MAINTENANCE SERVICE AND TROUBLE SHOOTING

Maintenance Service and Trouble Shooting

12.1.13 Procedure for temperature controller change

26

PDF created with pdfFactory trial version www.pdffactory.com

Page 27
Image 27
Haier BD-478A service manual Procedure for fan change, Procedure for temperature controller change