If electricity leakage occurs outside the compressor, please use

(1)Leakage of compressor: mainly because of serious vibration, the motor coil of compressor contacts with the shell, the coat of enameled wire will come off some where and connect with shell. Other reasons may be over voltage, insufficient of voltage, adverse circumstances (temperature too high, ventilation and heat radiation to bad) for freezer, thermal protection unit out of order, etc. They will make the motor coil over temperature, insulation material loose, insulation is damaged then electricity will occur.

(2)Leakage of motor connection terminals: the connection terminals of fully enclosed compressor are made from high temperature soda glass sintered ceramics, around the terminals are filled with a high polymer. The terminals and insulation material must have the same linear expansion coefficient, the for requirement between terminals and the shell is more than 0.5 million ohm. The reason of terminal leakage is that soda glass is broken or there are conductive materials such as water, dirt, etc., adhered to terminals.