(3) Filling

Determine the filling quantity first according to the freezer being repaired. (Each small mark of the liquid tube is 25g, each big mark is 100g).

Open all related valves.

When the liquid level has reached filling quantity, close valves.

(4) Test run

After filling, turn on power to freezer for test run. Observe the unit operation.

Switch off power.

12.6 Freezer noise

12.6.1 Freezer noise sources

Freezer noise comes from the expanding with heat and contracting with cold of compressor, evaporator or condenser; from the contacting or resonance of pipes; from the flowing of refrigerant; or from the vibration of freezer because the floor is not level, etc.

MAINTENANCE SERVICE AND TROUBLE SHOOTING

Maintenance Service and Trouble Shooting

12.6.2 Compressor

39