Haier BD-478A Maintenance Service And Trouble Shooting, Maintenance Service and Trouble Shooting

Models: BD-478A

1 61
Download 61 pages 29.49 Kb
Page 55
Image 55
a. Its temperature;

 

Dimensions (mm)

Mass (g)

Note

 

Small

25×50×100

125

In the geometrical center of 5oog

 

 

Middle

50×100×100

500

pack, there is a thermal element;

 

Big

50×100×200

1000

this pack is called M pack.

 

 

 

 

 

 

The contents of test packs are (take 1000g pack as the datum): hydroxyethlmethylcellulose 230g; water 764.2g; sodium chloride 5g; parachlorometacresol 0.8g. The freezing point of filling of pack is -1, its thermal property is similar to lean beef.

(5)Temperature measuring gauge: The measuring of temperature normally use platinum resistor. There are two types:

Put the platinum resistor directly into test pack (M pack) when measuring

a. Its temperature;

b.Insert the platinum resistor into the center of four tin electroplated copper columns, the diameter and height of column is the same 15.2mm.

The measuring equipment is temperature-measuring bridge with the accuracy of +-0.3K.

MAINTENANCE SERVICE AND TROUBLE SHOOTING

Maintenance Service and Trouble Shooting

(6)Humidity measuring instrument: the measurement of relative humidity is wet and dry bulb method. Put the dry bulb thermometer and wet bulb thermometer (enclose 1.5-2 layers of degreased gauze at the temperature

54

PDF created with pdfFactory trial version www.pdffactory.com

Page 55
Image 55
Haier BD-478A Maintenance Service And Trouble Shooting, Maintenance Service and Trouble Shooting, a. Its temperature