Haier CWH24A, CWH12A Location Requirements, Through-the-WallInstallation, Window Installation

Models: CWH24A CWH18A CWH12A

1 43
Download 43 pages 10.44 Kb
Page 5
Image 5
Location Requirements

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Check the location where air conditioner will be installed. Proper installation is your responsibility. Make sure you have everything necessary for correct installation.

The location should provide:

Grounded electrical outlet within 4 ft (122 cm) of where the power cord exits the air conditioner.

NOTE: Do not use an extension cord.

Free movement of air in room to be cooled.

A large enough opening for the air conditioner.

Adequate wall support for weight of air conditioner. Air conditioner weighs between :

CWH12A

5 and 115 lbs (43.1 to 52.2kg)

CWH18A

110 and 130 lbs (49.9 to 59 kg)

CWH24A

145 and 200 lbs (65 to 96 kg)

NOTE: Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers.

A

Through-the-Wall Installation

The wall opening measurements should be:

CWH12A

Width:23" (58.4 cm) plus twice thickness of wood used to build frame.

Height: 16" (40.6 cm) plus twice thickness of wood used to build frame.

Depth: Dimension for depth depends on the wall thickness and the type of molding.

CWH18A

Width:26¹⁄4 " (66.7 cm) plus twice thickness of wood used to build frame.

Height: 18 34 " (47.6 cm) plus twice thickness of wood used to build frame.

Depth: Dimension for depth depends on the wall thickness and the type of molding.

CWH24A

Width:2634" (67.9 cm) plus twice thickness of wood used to build frame.

Height: 18 34 " (47.6 cm) plus twice thickness of wood used to build frame.

Depth: Dimension for depth depends on the wall thickness and the type of molding.

A. Cabinet louvers

Window Installation

C

A

B

D

Window opening measurements:

 

 

CWH12A :

C

 

 

 

 

Model

CWH12A

CWH18A

CWH24A

A.16" (40.6 cm)

C. Wood thickness

B. 23"(58.4 cm)

D. Depth

Size

Opening width

28¹⁄2 " to 40"

28 " to 42"

30" to 43"

CWH18A :

 

(72.4 to 101.6 cm)

(71 to 106.7 cm)

(76.2 to 109.2 cm)

3

C. Wood thickness

 

 

 

 

A.18 4 " (47.6 cm)

Opening height

17¹⁄4" (43.8 cm)

19" (48.3 cm)

19¹⁄8" (48.6 cm)

B. 26 14 "(66.7 cm)

D. Depth

A (minimum)

28¹⁄2 " (72.4 cm)

28 " (71 cm)

B (minimum)

17¹⁄4 " (43.8 cm)

19 " (43.8 cm)

 

A

 

 

B

 

30 " (76.2 cm)

CWH24A :

 

A.16 34 " (47.6 cm)

C. Wood thickness

 

19¹⁄8 " (48.6 cm)

B. 2334"(67.9 cm)

D. Depth

4

Page 5
Image 5
Haier CWH24A, CWH12A, CWH18A manual Location Requirements, Through-the-WallInstallation, Window Installation