WARNING

Electrical Shock Hazard

WARNING

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

To test your power supply cord:

1. Plug the power supply cord into a grounded 3 prong outlet.

2.Press RESET (on some devices, a green light will turn on).

3.Press TEST (listen for click; Reset button will trip, and on some devices, a green light will turn off).

4.Press and release RESET (listen for click; Reset button will latch, and on some devices, a green light will turn on). The power supply cord is ready for operation.

NOTES:

The Reset button must be pushed in for proper operation.

The power supply cord must be replaced if it fails to trip when the test button is pressed or fails to reset.

Do not use the power supply cord as an off/on switch. The power supply cord is designed as a protective device.

A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired.

The power supply cord contains no user serviceable parts. Opening the tamper-resistant case voids all warranty and performance claims.

INSTALLATION INSTRUCTIONS

Unpack the Air Conditioner

WARNING

Excessive Weight Hazard

Use two or more people to move and install air conditioner.

Failure to do so can result in back or other injury.

* CWH18A:

Remove the screws inside the front panel that attach

the cabinet to the base on both sides.

Remove packaging materials

Remove and dispose of/recycle packaging materials. Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water and dry.

Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your air conditioner.

Handle the air conditioner gently.

1.Remove the air conditioner from the carton and place it on cardboard.

2.Remove the screws that attach the front panel to the air conditioner cabinet on both sides of the air conditioner.

3.* CWH12A,CWH24A:

Remove the screws that attach the air conditioner cabinet to the base on both sides of the air conditioner.

A

A. Screw locations

A

A. Screw locations

4.Remove the front panel from the air conditioner .

5.Disconnet conneting wire and set the front panel aside.

Connecting wire

6.Remove the ground screw and ground wire from the front of the air conditioner. Save the ground screw.

A

B

A. Green ground wire

B. Ground screw

6

Page 7
Image 7
Haier CWH18A, CWH12A, CWH24A manual Unpack the Air Conditioner, To test your power supply cord, Remove packaging materials