Programming Guide

Level I Programming

Parameters

P1 Time of day

P2 Time of regeneration

P3 Water hardness (grains per gallon—gpg)

P4 Salt usage per regeneration (lbs)

P5 System capacity (Kg)

Table 3: Level I programming parameters overview.

Default settings for models: SA-HB-40-DB-CERT (40DB) SA-HB-48-DB-CERT (48DB) (Ultra-high efficiency settings)

Setting

Description

40DB

48DB

 

 

 

 

P1

Time of day

Set to current time of day

 

 

 

 

P2

Time of regeneration

2 a.m.

2 a.m.

 

 

 

 

P3

Water hardness

Set in field

Set in field

 

 

 

 

P4*

Salt usage

3.0 lbs

3.6 lbs

 

 

 

 

P5

System capacity

14.1 Kg

15.2 Kg

 

 

 

 

Table 4: Level I programming default settings.

* Default settings are representative of ultra-high efficiency.

Level I Settings are identified as those that have an LED indicator on the front panel. The green indicator illuminates next to the name of the active control setting. (See Figure 19.)

Pressing the down arrow [$] button displays the Level I settings in order. By continuing to press the down arrow [$] button, the settings start over beginning with the time of day. Pressing the up arrow [#] button displays the settings in reverse order.

Figure 19: Control valve interface.

Level I Programming

Parameters

P1 Time of Day AM or PM

Ranges: 1:00 to 12:59 or 00:00 to 23:59

Minimum Increments: 1 Min.

Units of Measure: Hours & Minutes

Range: Depends on the value selected for P13

P2 Time of Regeneration

Ranges: 1:00 to 12:59 a.m. or p.m, 00:00 to 23:59

Minimum Increments: 1 Min.

Units of Measure: Hours & Minutes

Range: Depends on the value selected for P13

P3 Water Hardness Setting

Range: 3 to 250 (grains per gallon) gpg / 30 to 2500 (milligrams per liter) Mg/L

Minimum Increments: 1 for (gpg), 10 for (Mg/L)

Units of Measure: Grains per gallon (gpg) / Milligram per liter (Mg/L)

Range: Unit of measure depends on the value selected for P12. Test water hardness (compensated hardness) and enter that value.

P4 Salt Amount (maximum)

Ranges: 0.5 to 99.5 (pounds) or 0.1 to 25.5 (kilograms)

Minimum Increments: 0.5 (pounds) or 0.1 (kilograms)

Units of Measure: Pounds or Kilograms

Range: Unit of measure and default depends on value selected for P12.

P5 System Capacity

Ranges: 0.1 to 140 Kgr or 0.01 to 14.0 Kgr

Minimum Increments: 0.1 Kgr or 0.01 Kgr

Units of Measure: Kgr or Kilograms

Range: Depends on value selected for P12