Programming Guide

Level II Programming

The Level II programming has been programmed by the manufacturer to the settings in Table 6. The changing of preset values can be done at this time. Refer to Level II programming parameters in Table 6 for options.

Note: It is not recommended that homeowners change these values without checking with local water-treatment professional for details. Incorrect programming can cause system malfunction and the possible need for a field service call to reprogram the system. System programming is not covered under warranty.

To access Level II programming, simultaneously hold down the up [#] and down [$] arrows. This will allow you to enter Level II settings P6 through P19. (See Table 6.)

Level II Programming

Parameters

Level II Programming Parameters

Parameter

Description

Range

Minimum

Units of

 

Notes

 

 

 

Increments

Measure

 

 

 

 

 

 

 

 

P6

Refill controller

1–99

1

gpm

.35 gpm, both models

 

 

 

 

 

 

P7

Brine draw value

1–99

1

Minutes

15, both models

 

 

 

 

 

 

P8

Not used

n/a

n/a

n/a

n/a

 

 

 

 

 

 

P9

Backwash time

3–30

1

Minutes

Skip this parameter to accept the default or enter a value

 

 

 

 

 

 

P10

Slow rinse time

8–125

1

Minutes

SA-HB-40-DB-CERT = 67

 

 

 

 

 

SA-HB-48-DB-CERT = 80

 

 

 

 

 

 

P11

Fast rinse time

2–19

1

Minutes

Skip this parameter to accept the default or enter a value

 

 

 

 

 

 

 

P12

Units of measure

0–1

1

 

0

= U.S.

 

 

 

 

 

1

= Metric

 

 

 

 

 

Skip this parameter to accept the default (U.S.)

 

 

 

 

 

 

 

P13

Clock mode

0–1

1

 

0

= 12-hour clock

 

 

 

 

 

1

= 24-hour clock

 

 

 

 

 

Skip this parameter to accept the default (12-hour)

 

 

 

 

 

 

 

P14

Calendar override

0–30

1

days

0

= no calendar override

 

 

 

 

 

Skip this parameter to accept the default (no override)

 

 

 

 

 

 

 

P15

Reserve type

0–3

1

 

0

= variable reserve

 

 

 

 

 

 

P16

Fixed reserve capacity

0–70

1

percent of

Description depends on the value entered for P15 (Reserve

 

or initial average

 

 

capacity

type). Skip this parameter to accept the default.

 

value

 

 

 

 

 

 

 

 

 

 

 

 

P17

Operation type

0–1

1

 

0

= Not used

 

 

 

 

 

1

= 5-cycle counter current

 

 

 

 

 

 

 

P18

Salt / capacity change

0–1

1

 

0

= none

 

lock out

 

 

 

1

= salt / capacity change locked out

 

 

 

 

 

Skip this parameter to accept the default (no lock out)

 

 

 

 

 

 

P19

Factory defaults

DO NOT

1

 

Loads in factory default values. DO NOT CHANGE THIS

 

 

CHANGE

 

 

PARAMETER.

 

 

 

 

 

 

 

Table 6: Level II programming parameters.

Hamilton Beach Owner’s Manual 15

Page 15
Image 15
Hamilton Beach SA-HB-40-DB-CERT manual Level II Programming Parameters