Programming Guide
Level I and II Default Settings
The following table represents preset values programmed into the systems at the factory for both levels I and II for the model shown. (See Table 7.)
Level I Parameters
Name | Description |
|
|
|
|
|
|
P1 | Time of day | Set in field | Set in field |
|
|
|
|
P2 | Time of regeneration | 2:00 a.m. | 2:00 a.m. |
|
|
|
|
P3 | Hardness | Set in field | Set in field |
|
|
|
|
P4 | Salt amount | 3.0 lbs | 4.0 lbs |
|
|
|
|
P5 | Capacity | 14.1 Kgr @ 3.0 lbs of salt | 15.2 Kgr @ 3.6 lbs of salt |
|
|
|
|
Level II Parameters |
|
| |
P6 | Refill controller | 0.35 gpm | 0.35 gpm |
|
|
|
|
P7 | Brine draw value | 3.0 lbs @ 7 min w/ 5 bump injector | 4.0 lbs @ 9 min w/ 5 bump injector |
|
| 7.5 lbs @ 26 min w/ 4 bump injector | 9.0 lbs @ 31 min w/ 4 bump injector |
|
| 15.0 lbs @ 51 min w/ 4 bump injector | 18.0 lbs @ 61 min w/ 4 bump injector |
|
|
|
|
P8 | Not used | n/a | n/a |
|
|
|
|
P9 | Backwash time | 3.9 min | 3.9 min |
|
|
|
|
P10 | Slow rinse time | 75.5 min @ 3.0 lbs with 5 bump injector | 75.5 min @ 3.0 lbs with 5 bump injector |
|
| 62.0 min @ 7.5 lbs with 4 bump injector | 62.0 min @ 7.5 lbs with 4 bump injector |
|
| 57.0 min @ 15.0 lbs with 4 bump injector | 57.0 min @ 15.0 lbs with 4 bump injector |
|
|
|
|
P11 | Fast rinse time | 3.5 min | 3.5 min |
|
|
|
|
P12 | Units of measure | 0 | 0 |
|
|
|
|
P13 | Clock mode | 0 | 0 |
|
|
|
|
P14 | Calendar override | 0 | 0 |
|
|
|
|
P15 | Reserve type | 0 | 0 |
|
|
|
|
P16 | Fixed reserve capacity | n/a | n/a |
| or initial average value |
|
|
|
|
|
|
P17 | Operation type | 1 | 1 |
|
|
|
|
P18 | Salt / capacity change | 0 | 0 |
| lock out |
|
|
|
|
|
|
P19 | Factory defaults | 9 | 9 |
|
|
|
|
Table 7: Level I and II programming default settings.
16 Hamilton Beach Owner’s Manual