Start Up Rinsing Procedure (con’t)

5.After the ten-minute backwash cycle, manually advance the control valve to the brine refill position for ten minutes allowing water to flow into the brine storage tank. (See Figure 13.)

7. Plug in the control valve. (See Figure 15.)

Figure 13

Once water begins to flow into the tank fill the brine tank with a minimum of 100 lbs of salt pellets.

6.After the ten-minute refill time, manually advance the control valve to the service position. (See Figure 14.)

Figure 14

Figure 15

8.If it is necessary to extend the length of the transformer cord, an optional 15 foot (4.6-m) extension cord is available, (See Figure 16), or the cord may be spliced as follows:

a.Strip insulation from wire 5/16 inch (7.87 mm) from wire end.

b.Insert stripped wire into barrel of connector and crimp. For best results, crimp twice per wire as shown in Figure 17 .

Neither splice connections nor extension wire are supplied. They are available at hardware or electrical stores.

Figure 16

(AVP-1000907)

Figure 17