Troubleshooting
Problem Description | Possible Cause | Solution |
|
|
|
• Control does not regenerate automatically | If water flow display is not operative, refer to | Refer to item 5 (“No water flow display when |
but does regenerate when [REGEN] button is | item 5 (“No water flow display when water is | water is flowing”) in this table |
depressed | flowing”) in this table |
|
|
|
|
| Incorrect hardness and capacity settings | Set new control |
|
| section |
|
|
|
| Defective circuit board | Replace control |
|
|
|
• Run out of soft water between regenerations | Improper regeneration | Repeat regeneration making certain correct salt |
|
| dosage is used |
|
|
|
| Fouled resin bed | Use resin cleaner |
|
|
|
| Incorrect salt setting | Set salt setting to proper |
|
| programming section |
|
|
|
| Incorrect hardness or capacity settings | Set to correct |
|
| section |
|
|
|
| Water hardness has increased | Set to new |
|
| section |
|
|
|
| Restricted meter turbine rotation due to foreign | Remove meter housing, free up turbine, and flush |
| material in meter housing | with clean water. Turbine should spin |
|
| replace meter |
|
|
|
| Water usage below 1/5 gallon per minute | Repair leaky plumbing and/or fixtures |
|
|
|
| Brine draw value from table 4 is incorrect | Set correct brine draw value |
|
|
|
| Incorrect salt type, or use of grid plate (salt shelf) | Do not use block salt or grid plate (salt shelf) in |
|
| brine tank |
|
|
|
• Control does not draw brine | Low water pressure | Increase water pressure (20 psi at conditioner) |
|
|
|
| Restricted drain line | Remove obstruction |
|
|
|
| Injector or injector screen is plugged | Clean injector and |
|
| the Injector / Injector Screen” section |
|
|
|
| Injector defective | Replace injector and cap |
|
|
|
| Valve disc 3 and/or 5 not closed | Manually operate cam gear to flush out foreign |
|
| matter holding disc open. Replace if needed |
|
|
|
| Air check valve prematurely closed | Briefly put control into brine refill status. Refer |
|
| to the “Manual Regeneration” section. Repair air |
|
| check valve if needed |
|
|
|
• Brine tank overflow | Brine valve disc 1 held open | Manually operate cam gear to flush out foreign |
|
| matter holding disc open |
|
|
|
| Valve disc 2 not closed during brine draw, | Manually operate cam gear to flush out foreign |
| causing brine refill | matter holding disc open |
|
|
|
| Air leak in brine line to air check | Check all connections in brine line for leaks |
|
|
|
| Salt setting too high | Set in new |
|
|
|
• Intermittent or irregular brine draw | Low water pressure | Increase water pressure (20 psi at conditioner) |
|
|
|
| Defective injector | Replace both injector and injector cap |
|
|
|
• No conditioned water after regeneration | Unit did not regenerate | Check for power |
|
|
|
| No salt in brine tank | Add salt to brine tank |
|
|
|
| Plugged injector | Remove injector and flush it and injector screen |
|
|
|
| Air check valve closed prematurely | Put control momentarily into REFILL to free air |
|
| |
|
|
|
| Incorrect salt type or use of grid plate (salt shelf) | Do not use block salt or grid plate (salt shelf) in |
| in brine tank | brine tank |
|
|
|